00194398-01.pdf - 第41页
Retrofit instructions SIPLACE HS-60 12/2004 Edition 2.3 Retrofit kits, tools 41 2.3 Retrofit kit s, tools 2.3.1 Retrofit kit s 2 Fig. 2.3 - 1 Retrofit kit for sing le conveyor + 1 lifting table 2 2 2 2 2 2 2 4 3 1a,b,c 1…

Retrofit instructions SIPLACE HS-60
2.2 Safety instructions 12/2004 Edition
40
2.2 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
SITEST must only be used by authorized and trained personnel.
2
2.2.1 Definitions
2
PLEASE NOTE 2
2
2
2
Caution 2

Retrofit instructions SIPLACE HS-60
12/2004 Edition 2.3 Retrofit kits, tools
41
2.3 Retrofit kits, tools
2.3.1 Retrofit kits
2
Fig. 2.3 - 1 Retrofit kit for single conveyor + 1 lifting table
2
2
2
2
2
2
2
4
3
1a,b,c
1f,h
1e
1d
1g
5

Retrofit instructions SIPLACE HS-60
2.3 Retrofit kits, tools 12/2004 Edition
42
2
2
2
The basic unit consists of the following parts: 2
2
Qty. Item number Designation
Spare part
00119471- HS60 ceramic substrate centering, single conveyor
2 03015184- Basic ceramic substrate centering unit
2 00366230- Raised cer. centering mode, complete
4 00845028- DIN912-M4 x 20-8.8
8 00366960- Travel limitation E
1 03013650- Tool for travel limitation E
2 00369722- Cable: ceramic substrate centering E
2 00367190- Lifting table bed, single conveyor option
1 00193890- Retro. instruct. for ceramic sub. option HS60
Qty. Item number Designation
Spare part
00119470- HS60 ceramic substrate centering, dual conveyor
2 03015184- Basic ceramic substrate centering unit
2 00366230- Raised cer. centering mode, complete
4 00845028- DIN912-M4 x 20-8.8
8 00366960- Travel limitation E
1 03013650- Tool for travel limitation E
2 00369722- Cable: ceramic substrate centering E
2 00367190- Lifting table bed, single conveyor option
1 00193890- Retro. instruct. for ceramic sub. option HS60
Item
Qty. Item number Designation Spare
part
1 03015184-xx Basic ceramic substrate centering unit
1a
1 00347287-xx X direction carriage unit, cer.cent. HS-50
1b
1 00347281-xx Base unit for cer. centering HS-50
1c
1 00358874-xx Stop set 1, cer.cent. HS-50 E
1d
1 00358875-xx Stop set 2, cer.cent. HS-50 E
1e
1 00358876-xx Stop set 3, cer.cent. HS-50 E
1f
1 00356032-xx-xx Pneumatic syst. ceramic cent. HS-50 E
1g
1 00332940-xx Solenoid valve MZH-5/2-M3-L-LED E
1h
1 00333778-xx Plastic hose PUN-6*1 blue E