Retrofit instructions SIPLACE HS-60 12/2004 Edition 2.5 Mechanical conversion 53 : Insert the travel limiter . Y ou must feel the compression spring snap into place. 2 : Remove the tool. : Insert two travel limiters per …

100%1 / 70
Retrofit instructions SIPLACE HS-60
2.5 Mechanical conversion 12/2004 Edition
52
2.5.2 Installing the lifting table travel limiter
2
2
: Use the tool to lift the compression spring on the PCB clamp as far as the stop.
2
2
PCB clamp
PCB clamp
Lift the compression spring
Travel limiter
Tools
Retrofit instructions SIPLACE HS-60
12/2004 Edition 2.5 Mechanical conversion
53
: Insert the travel limiter. You must feel the compression spring snap into place.
2
: Remove the tool.
: Insert two travel limiters per conveyor side wall and placement area.
: If you wish to remove the travel limiters, insert the tool over the limiter and then pull the spring
up.
The travel limiter can then be pulled out at the side.
2
Make sure that the spring does not jump out. It must be lowered correctly back into a groove or
placed around the pins. 2
2
Please contact Siemens L&A Product Management if you need to place the PCBs right up to the
edge. 2
2
: Close the covers over the cable ducts.
: Refit the lifting tables into the placement machine and bolt in place.
2
2
2
2
2
2
2
00366960-02 Travel limiter 2.5 mm for SIPLACE HS-60 / S-27 HM
Retrofit instructions SIPLACE HS-60
2.5 Mechanical conversion 12/2004 Edition
54
: In placement area 1, run the hoses and cables in the groove beneath the base.
2
2
: In placement area 2, the cable and hose may be attached directly.
2
Base
Run cables and hoses
beneath the base
Carriage unit