Retrofit instructions SIPLACE HS-60 2.4 Preparatory work 12/2004 Edition 44 2.4 Prep aratory work 2 The lifting t able beds must be / remain lowered so that there is no strain on the termina l blocks. 2 2 : Set the PCB c…

100%1 / 70
Retrofit instructions SIPLACE HS-60
12/2004 Edition 2.3 Retrofit kits, tools
43
2
2
2.3.2 Additional materials required
For each ceramic substrate centering unit: 2
- Cable ties L x W = 140 x 3.6mm Item no. 00805141-01
- Fixing base, self-adhesive Item no. 00805103-01
2.3.3 Tools and testing aids, consumables
Set of hexagon socket spanners
Set of screwdrivers
Set of diagonal cutters
Tool for travel limiter (included in package) Item no. 03013650-01
Qty.
Item number Designation Spare
part
00347284-01 Fixed stop wearing part CerCent HS50 E
00318145-01 Sensor: ceramic substrate centering E
00332940-01 Solenoid valve MZH-5/2-M3-L-LED E
00366960-02 Travel limiter 2.5 mm E
03013650-01 Tool for travel limitation E
00369722-01 Cable: ceramic substrate centering E
Retrofit instructions SIPLACE HS-60
2.4 Preparatory work 12/2004 Edition
44
2.4 Preparatory work
2
The lifting table beds must be / remain lowered so that there is no strain on the terminal blocks.2
2
: Set the PCB conveyor to maximum width.
: Switch the placement machine off at the main switch.
2
: Screw the solenoid valve onto the supporting plate using two screws (see photograph below).
The terminals of the solenoid valve are assigned as follows: 2
2
2.5 Mechanical conversion
2.5.1 Replacing the lifting table beds
: Loosen and remove the 4 hexagon socket head screws used to fix the lifting table bed to the
lifting table unit.
2
There is a risk of crushing / cuts while lifting out the lifting table beds, particularly between the outer
edges of the lifting table bed and the conveyor modules. 2
See also pneumatic drawing in Section 2.8. 2
Compressed air outlet
Silencer
Compressed air inlet
Screws
Retrofit instructions SIPLACE HS-60
12/2004 Edition 2.5 Mechanical conversion
45
: Disconnect the main compressed air supply to the lifting tables in placement area 1.
2
: Insert the T-piece provided and the four-way or two-way distributor between the compressed
air line and main supply to the lifting tables, as shown in the picture.
2
2
2
Main compressed air supply to lifting tables