00198376-01_UM_TouchlessPlacement-R17-1_DE_EN.pdf - 第31页
Programming in SIPLACE Pro Defining Height Measurement Points Touchless Placement (R17-1) Ber ührungsloses Bestücken (R17-1 ) 31 Height Measurement Points for Grid Boards ► Open the required grid b oard (1) in the SIPLAC…

Programming in SIPLACE Pro
Defining Height Measurement Points
30 Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1)
Height Measurement Points for Boards
► Open the required board (1) in the SIPLACE Pro Board Editor.
Board Editor – Defining Height Measurement Points
► Select the Fiducials tab (2) on the board side or panel.
► In the Height Measurement Points table (3), define at least three height measurement points to
measure the height for contactless component placement.
Table: Height Measurement Points
Field Value/Meaning
Reference designator Enter the unique designator for the height meas-
urement point here. This designator is to represent
the position of the height measurement point on
the board.
X Position of the height measurement point in X di-
rection with regards to the position of the current
panel or board.
Y Position of the height measurement point in Y di-
rection with regards to the position of the current
panel or board.
Disable Disables this height measurement point for meas-
urement.
Adds a new line to the table.
Removes a selected line from the table.

Programming in SIPLACE Pro
Defining Height Measurement Points
Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1) 31
Height Measurement Points for Grid Boards
► Open the required grid board (1) in the SIPLACE Pro Grid Board Editor.
Grid Board Editor – Defining Height Measurement Points
► Select the PCB Fiducials tab (2) or the Panel Type Fiducials tab.
► In the Height Measurement Points table (3), define at least three height measurement points to
measure the height for contactless component placement.
Table: Height Measurement Points
Field Value/Meaning
Reference designator Enter here the unique designator for the height
measurement point. This designator is to repre-
sent the position of the height measurement point
on the grid board
X Position of the height measurement point in X di-
rection with regards to the position of the current
grid board.
Y Position of the height measurement point in Y di-
rection with regards to the position of the current
grid board.
Disable Disables this height measurement point for meas-
urement.
Adds a new line to the table.
Removes a selected line from the table.
Programming in SIPLACE Pro
Defining Height Measurement Points
32 Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1)