Programming in SIPLACE Pro Defining Height Measurement Points Touchless Placement (R17-1) Ber ührungsloses Bestücken (R17-1 ) 31 Height Measurement Points for Grid Boards ► Open the required grid b oard (1) in the SIPLAC…

100%1 / 38
Programming in SIPLACE Pro
Defining Height Measurement Points
30 Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1)
Height Measurement Points for Boards
Open the required board (1) in the SIPLACE Pro Board Editor.
Board Editor – Defining Height Measurement Points
Select the Fiducials tab (2) on the board side or panel.
In the Height Measurement Points table (3), define at least three height measurement points to
measure the height for contactless component placement.
Table: Height Measurement Points
Field Value/Meaning
Reference designator Enter the unique designator for the height meas-
urement point here. This designator is to represent
the position of the height measurement point on
the board.
X Position of the height measurement point in X di-
rection with regards to the position of the current
panel or board.
Y Position of the height measurement point in Y di-
rection with regards to the position of the current
panel or board.
Disable Disables this height measurement point for meas-
urement.
Adds a new line to the table.
Removes a selected line from the table.
Programming in SIPLACE Pro
Defining Height Measurement Points
Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1) 31
Height Measurement Points for Grid Boards
Open the required grid board (1) in the SIPLACE Pro Grid Board Editor.
Grid Board Editor – Defining Height Measurement Points
Select the PCB Fiducials tab (2) or the Panel Type Fiducials tab.
In the Height Measurement Points table (3), define at least three height measurement points to
measure the height for contactless component placement.
Table: Height Measurement Points
Field Value/Meaning
Reference designator Enter here the unique designator for the height
measurement point. This designator is to repre-
sent the position of the height measurement point
on the grid board
X Position of the height measurement point in X di-
rection with regards to the position of the current
grid board.
Y Position of the height measurement point in Y di-
rection with regards to the position of the current
grid board.
Disable Disables this height measurement point for meas-
urement.
Adds a new line to the table.
Removes a selected line from the table.
Programming in SIPLACE Pro
Defining Height Measurement Points
32 Touchless Placement (R17-1) Berührungsloses Bestücken (R17-1)