A16-F-R-00-H-S-K-A200-32408柱塞泵资料.pdf - 第29页
53 PIST ON PUMPS A Series A Series V ariable Displacement Piston Pumps Solenoid T wo Pressure Control T ype A Series V ariable Displacement Piston Pumps, Solenoid T wo Pressure Control T ype Graphic Symbol Performance Ch…

52
A
Series Variable Displacement Piston Pumps
■ Spare Parts List
A145-*R01*S
X X
53
19
45
24
62
18 43 59
21
56 22 17 50 48
47
49 66 20
57
23
74
2 40 6 34 11 32 30 13 38 10 12 16 31
72
57
71
44
64
4
68
41
54
39
9
61159528
7337
603698466356
365258
75
14
46
62
25
65
29
27
67
35
70
75
51
65
15 7 33
76
Section X-X
Item Name of Parts Part Numbers Qty.
6 Gasket 1312-PK211974-1 1
15 Back Up Ring 1310E-PK412440-0 1
39 Bearing NUP 2211ET2 1
40 Needle Bearing 8Q-NK38×55×30 1
41 Oil Seal TCN 507212 (FKM) 1
43 O-Ring S-31.5 (NBR-70) 1
44 O-Ring SO-FA-G105 1
45 O-Ring SO-NA-P18 1
46 O-Ring SO-NB-P9 2
47 O-Ring AS568-017 (NBR-70) 1
48 O-Ring AS568-016 (NBR-70) 1
49 Back Up Ring For AS568-017 (NBR-70) 1
50 Back Up Ring For AS568-016 (NBR-70) 1
73 O-Ring SO-NB-P18 1
76 O-Ring SO-NB-P5 1

53
PISTON PUMPS
A Series
A
Series Variable Displacement Piston Pumps
Solenoid Two Pressure Control Type
A
Series Variable Displacement Piston Pumps, Solenoid Two Pressure Control Type
Graphic Symbol
Performance Characteristics
SOL
"OFF"
SOL
"ON"
PL PH
PL
PH
M
O
Pressure
Output Flow
■ Specifications
Model Numbers
Geometric
Displacement
cm
3
/rev
Minimum
Adj. Flow
cm
3
/rev
Operating Pressure
MPa
Minimum
Adj. Pres.
MPa
Shaft Speed Range
r/min
Approx. Mass
kg
Rated
★2
Intermittent
★1
Max. Min. Flange Mtg. Foot Mtg.
A16-
*
-R-02-
*
-K
*
-32 15.8 4 16 21 1.2 1800 600 24.5 26.7
A22-
*
-R-02-
*
-K
*
-32 22.2 6 16 16 1.2 1800 600 24.5 26.7
A37-
*
-R-02-
*
-K
*
-32 36.9 10 16 21 1.2 1800 600 36 40.3
A56-
*
-R-02-
*
-K
*
-32 56.2 12 16 21 1.2 1800 600 43 47.3
A70-
*
R02S
*
-60 70.0 36 25 25 2 1800 600 63.5 75.5
A90-
*
R02S
*
-60 91.0 56 25 25 2 1800 600 80.5 101
A145-
*
R02S
*
-60 145 83 25 25 2 1800 600 97.5 122.5
★1. Whenever setting pressure, make sure the full cut-off pressure never exceeds the maximum intermittent pressure.
★2. When operating the pump exceeding the rated pressure, operating conditions are restricted. Refer to page 31 for the details.
■ Solenoid Ratings
Electric source Coil Type
Frequency
(Hz)
Voltage (V) Current & Power at Rated Voltage
Source Rating Serviceable Range Inrush (A)
★2
Holding (A) Power (W)
AC
A100
50 100 80 - 110 2.42 0.51
—
60
100
90 - 120
2.14 0.37
110 2.35 0.44
A120
50
120
96 - 132 2.02 0.42
60 108 - 144 1.78 0.31
A200
50 200 160 - 220 1.21 0.25
60
200
180 - 240
1.07 0.19
220 1.18 0.22
A240
50
240
192 - 264 1.01 0.21
60 216 - 288 0.89 0.15
DC (K Series)
D12
—
12 10.8 - 13.2
—
2.45
29D24 24 21.6 - 26.4 1.23
D48 48 43.2 - 52.8 0.61
AC
→
DC Rectied(R)
★1
R100
50/60
100 90 - 110
—
0.33
29
R200 200 180 - 220 0.16
★1. R type models with built-in current rectifier is recommended for shockless operation with AC power.
★2. Inrush current in the above table show rms values at maximum stroke.

54
A
Series Variable Displacement Piston Pumps
Solenoid Two Pressure Control Type
■ Model Number Designation
A16 -F -R -02 -S -K -A100 -32
Series Number Mounting
Direction of
Rotation
Control Type Port Position
Shaft
Extension
Coil Type of
Solenoid Valve
Design
Number
A16
(15.8 cm
3
/rev)
F: Flange
Mtg.
L: Foot
Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
(Normal)
02:
Solenoid Two
Pressure Control
Type
None:
Axial Port
S: Side Port
K:
Keyed Shaft
AC
A100, A120
A200, A240
DC
D12, D24
D48
R (AC→DC Rectified)
R100, R200
32
A22
(22.2 cm
3
/rev)
32
A37
(36.9 cm
3
/rev)
32
A56
(56.2 cm
3
/rev)
32
A70 -F R 02 S A100 -60
Series Number Mounting
Direction of
Rotation
Control Type Port Position
Coil Type of
Solenoid Valve
Design
Number
A70
(70.0 cm
3
/rev)
F: Flange
Mtg.
L: Foot
Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
(Normal)
02:
Solenoid Two Pressure
Control Type
S: Side Port
AC
A100, A120
A200, A240
DC
D12, D24
D48
R (AC→DC Rectified)
R100, R200
60
A90
(91.0 cm
3
/rev)
60
A145
(145 cm
3
/rev)
60
★1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
■ Performance Characteristics
For performance characteristics, refer to models of pressure compensator type on page 35 to 42.
■ Pipe Flange Kits
For Pipe flange, refer to form of pressure compensator type on page 32.