A16-F-R-00-H-S-K-A200-32408柱塞泵资料.pdf - 第55页
79 PIST ON PUMPS A Series A Series V ariable Displacement Piston Pumps Electro-Hydraulic Propor tional Pressure & Flo w Control T ype YUKEN 13 58.7 299.5 357.5 30.2 24 70 110 112 23 89 370.5 228.6 (273) 141 219 299.5…

78
A
Series Variable Displacement Piston Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type
X
M10 Thd. 19 Deep
4 Places
Suction Port
35 Dia.
End Cover
Seal Cover
Plain Washer
Outboard
Pump Position
M10 Thd. 19 Deep
4 Places
Discharge Port
32 Dia.
Hex. Hd. Screw
“DR”
“DR”(with Plug)
Air Vent
3 Hex. Soc.
Filling Port
★1
(22 Hex. Head Plug Furnished)
Pressure Sensor
Connector
Tilt Angle Sensor Connector
★3
★3
R14
58.7
30.2
191
174
146
265
58.7
30.2
191
12
50.5
62
9.5
40
90
287
98
41 49
14
25
100 100
163.5151.5
191
Drain Port
★2
Rc
3/4 Thd. 2 Places
7.97
7.94
31.75
31.70
Dia.
35.32
35.14
101.60
101.55
Dia.
Cable Departure
★4
Cable Applicable :
Outside Dia. ..... 8 - 10 mm
Conductor Area
.....Not Exceeding 1.5mm
2
120Dia.
Flange Mtg. : A56-FR04E*
YUKEN
X
Filling Port
★1
(22 Hex. Head Plug Furnished)
"S"“P”
M10 Thd. 17 Deep
4 Places
Case Drain Port
★3
5 Hex. Soc.
“DR” (with Plug)
M12 Thd. 19 Deep
4 Places
Discharge Port
26 Dia.
Suction Port
38 Dia.
Eye Bolt
M10
35 Dia. Spotface
(Rear Side)
2 Places
Outboard Pump
Position
Hex. Hd. Screw
Plain Washer
End Cover
Seal Cover
Tilt Angle Sensor
Connector
Pressure Sensor
Connector
“DR”
19.5
9.5
90
62
40
18
69.9
73
9595
73
157
118
181
211
18
180
65
246.5
26.2
52.4
246.5
35.7
305.5
345.5
207.5
116.5
Air Vent
3 Hex. Soc.
7.97
7.94
Drain Port
★2
Rc
3/4 Thd. 2 Places
★3
★3
★5
31.75
31.70
Dia.
35.32
35.14
127.00
126.95
Dia.
Cable Departure
★4
Cable Applicable :
Outside Dia. ..... 8-10 mm
Conductor Area
.....Not Exceeding 1.5mm
2
Flange Mtg. : A70-FR04E*
View Arrow X
View Arrow X
● Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 46 for the dimensions of mounting bracket.
● Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 47 for the dimensions of mounting bracket.
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option. Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option.
Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
★5. If you do not use the special sequence valve, plug the port (FP-SC-1/32).
DIMENSIONS IN
MILLIMETRES
DIMENSIONS IN
MILLIMETRES

79
PISTON PUMPS
A Series
A
Series Variable Displacement Piston Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type
YUKEN
13
58.7
299.5
357.5
30.2 24
70
110
112
2389
370.5
228.6
(273)
141 219
299.5
42.9
77.8
171.5
72
112
72
112
M10 Thd. 19 Deep
4 Places
M12 Thd. 19 Deep
4 Places
Discharge Port
32 Dia.
R22
Case Drain Port
5 Hex. Soc.
Suction Port
48 Dia.
Eye Bolt
M10
Tilt Angle Sensor
Connector
Pressure Sensor
Connector
Air Vent
3 Hex. Soc.
Drain Port
★2
Rc
3/4 Thd. 2 Places
Outboard Pump
Position
21.5 Dia. Through
39 Dia. Spotface
(Rear Side)
4 Places
Filling Port
★1
(27 Hex. Head Plug Furnished)
Surface of Discharge Port
Surface of Drain Port Surface of Drain Port
(with Plug)
Surface of Suction Port
11.14
11.11
379.5:A145-FR04E*A
383:A145-FR04E*B
Hex. Hd. Screw
Plain Washer
End Cover
Seal Cover
228.6
★5
★3
★3
Cable Departure
★4
Cable Applicable :
Outside Dia. ..... 8-10 mm
Conductor Area
.....Not Exceeding 1.5mm
2
44.45
44.40
Dia.
49.39
49.21
152.40
152.35
Dia.
YUKEN
217
117.5 157
359
324
113
63
13
23
95
119.5
127
68 68
105105
161.6
270
77.8
58.7
9.56
9.53
M10 Thd. 19 Deep
4 Places
Discharge Port
32 Dia.
Outboard Pump
Position
Case Drain Port
★3
5 Hex. Soc.
Air Vent
3 Hex. Soc.
21.5 Dia. Through
39 Dia. Spotface
(Rear Side)
4 Places
Filling Port
★1
(27 Hex. Head Plug
Furnished)
M12 Thd. 19 Deep
4 Places
Eye Bolt
M10
Tilt Angle Sensor
Connector
Pressure Sensor
Connector
Suction Port
48 Dia.
X
30.2
23
R22
42.9
270
Surface of Drain Port
Surface of Drain Port
(with Plug)
Hex. Hd. Screw
Plain Washer
End Cover
Seal Cover
161.6
Drain Port
★2
Rc
3/4 Thd. 2 Places
★3★3
★5
Cable Departure
★4
Cable Applicable :
Outside Dia. ..... 8-10 mm
Conductor Area
.....Not Exceeding 1.5mm
2
38.10
38.05
Dia.
42.36
42.18
152.40
152.35
Dia.
Flange Mtg. : A90-FR04E**
A100-FR04E**
Flange Mtg. : A145-FR04E**
● Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 48 for the dimensions of mounting bracket.
● Foot Mounting Type
Mounting bracket is common to that of pressure compensator model.
Refer to page 49 for the dimensions of mounting bracket.
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option.
Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
★5. If you do not use the special sequence valve, plug the port (FP-SC-1/32).
★1. Install the pump so that the “Filling Port” is at the top.
★2. Use either port of two drain ports at your option.
Keep the remaining port plugged.
★3. Do not touch the screw because it is adjusted at the time of shipment.
★4. For cable connection with amplifiers, see page 81.
★5. If you do not use the special sequence valve, plug the port (FP-SC-1/32).
View Arrow X
DIMENSIONS IN
MILLIMETRES
DIMENSIONS IN
MILLIMETRES

80
A
Series Variable Displacement Piston Pumps
Electro-Hydraulic Proportional Pressure & Flow Control Type
FUSE
1 1 1 1 1
POWER
電 源/POWERSUPPLY
CN2
ソレノイド/SOLENOID
CN1
FUSE
(5A)
圧力
センサ/PRESSURESENSOR
CN3
04EPUMP
CONTROLLER
信号/I/OSIGNAL
CN5
TP1
P.S.ZERO
P.S.GAIN
Q.S.ZERO
Q.S.GAIN
斜板角センサ/TILTANGLESENSOR
CN4
YUKENKOGYOCO.,LTD.
MADEINJAPAN
PUMPMFGNO.
AMP.MFGNO.
MODEL
SK1106-***-***-**-10
EK411027-6
P.SPAN
Q.MIN
Q.SPAN
P.MIN
M.GAIN
P.GAIN
Q.COMP
L.Q.C
Q.GAIN
Q.DOT
CN1
Solenoid
CN2
Power Supply
Frequency
Select Switch
View with the Cover Removed
Fuse
CN3
Pres. Sensor
CN4
Tilt Angle Sensor
CN5
Input/
Output
Signal
Connector
140
165
15
5
48
92
100
SK1106-★-*-*-10**
● Specifications ● Detail of Connector
Model No.
Description
SK1106-★-*-*-10**
Applicable Coil
Resistance
10 Ω (20℃)
Input Impedance 10 kΩ (PIN, QIN)
Power Supply
24 V DC
(21 - 28 V Included Ripple)
Power Input (Max.) 30 W
Input Signal
Max. Flow / 5 V (QIN)
Specified Pres. / 5 V (PIN)
Output Signal for Sensor
Monitor
5 V / Max. Flow (SMQ)
5 V / Specified Pres. (SMP)
Ambient Temperature 0 - 50 ℃
Approx. Mass 450 g
Connector Name of Signal
CN1
Solenoid
1
Output to pilot valve solenoid
2
CN2
Power
Supply
1 0
[
V
] (
0 V
)
2
+
24
[
V
] (
24 V
)
3
0
[
V
]
CN3
Pres.
Sensor
1
+
5
[
V
]
Power Supply for Sensor
2
0
[
V
]
3 Input Signal - Sensor
4
0
[
V
]
CN4
Tilt
Angle
Sensor
1
+
8
[
V
]
Power Supply for Sensor
2
0
[
V
]
3 Input Signal - Sensor
4
0
[
V
]
5 —
CN5
Input/
Output
Signal
1 Input Signal - Flow
(
Qin
)
2 Input Signal - Common
(
COM
)
3 Input Signal - Pres.
(
Pin
)
4 Output Signal - Sensor Monitor P
(
SMP
)
5 Output Signal - Sensor Monitor Q
(
SMQ
)
6
0
[
V
]
■ Amplifiers for Electro-Hydraulic Proportional Pressure & Flow Control Type Pumps