62 A Series V ariable Displacement Piston Pumps Propor tional Electro-Hydraulic Load Sensing T ype A Series V ariable Displacement Piston Pumps, Proportional Electro-Hydraulic Load Sensing T ype Graphic Symbol Performanc…

100%1 / 89
61
PISTON PUMPS
A Series
A
Series Variable Displacement Piston Pumps
Pressure Conpensator with Unloading Type
A
Series Variable Displacement Piston Pumps,
Pressure Compensator with Unloading Type
Graphic Symbol
Performance Characteristics
SOL
"OFF"
SOL
"ON"
Pressure
Output Flow
M
O
Specifications
Model Numbers
Geometric
Displacement
cm
3
/rev
Minimum Adj.
Flow
cm
3
/rev
Operating Pressure
MPa
Unloading Pressure
MPa
Shaft Speed Range
r/min
Rated Intermittent Max. Min.
A16-
-R-03-
-K-
-32 15.8 4 16 21 1.2 1800 600
A22-
-R-03-
-K-
-32 22.2 6 16 16 1.2 1800 600
A37-
-R-03-
-K-
-32 36.9 10 16 21 1.2 1800 600
A56-
-R-03-
-K-
-32 56.2 12 16 21 1.2 1800 600
A70-
R03S
-60 70.0 36 25 25 1.2 1800 600
A90-
R03S
-60 91.0 56 25 25 1.2 1800 600
A145-
R03S
-60 145 83 25 25 1.2 1800 600
Model Number Designation
A16 -F -R -03 -S -K -A100 -32
Series Number Mounting
Direction of
Rotation
Control Type Port Position
Shaft
Extension
Coil Type of
Solenoid Valve
Design
Number
A16
(15.8 cm
3
/rev)
F: Flange
Mtg.
L: Foot
Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
(Normal)
03:
Pressure
Compensator
with
Unloading Type
None:
Axial Port
S: Side Port
K:
Keyed Shaft
AC
A100, A120
A200, A240
DC
D12, D24
D48
R (ACDC Rectified)
R100, R200
32
A22
(22.2 cm
3
/rev)
32
A37
(36.9 cm
3
/rev)
32
A56
(56.2 cm
3
/rev)
32
A70 -F R 03 S A100 -60
Series Number Mounting
Direction of
Rotation
Control Type Port Position
Coil Type of
Solenoid Valve
Design
Number
A70
(70.0 cm
3
/rev)
F: Flange Mtg.
L: Foot Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
(Normal)
03:
Pressure Compensator
with
Unloading Type
S: Side Port
AC
A100, A120
A200, A240
DC
D12, D24
D48
R (ACDC Rectified)
R100, R200
60
A90
(91.0 cm
3
/rev)
60
A145
(145 cm
3
/rev)
60
1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
2. Please inquire for A220 separatery.
Consult Yuken when detailed material such as dimensions figures is required.
62
A
Series Variable Displacement Piston Pumps
Proportional Electro-Hydraulic Load Sensing Type
A
Series Variable Displacement Piston Pumps,
Proportional Electro-Hydraulic Load Sensing Type
Graphic Symbol
Performance Characteristics
Pressure
Output Flow
Input
Current i
(Small
Large)
1
Input
Current i
(Small
Large)
2
M
O
1
2
M
O
1
2
A70/A90/A145
A16/A22/A37/A56
Model Number Designation
A56 -F -R -04 -C -K -32
Series Number Mounting
Direction of
Rotation
Control Type Pressure Adj. Range MPa Shaft Extension
Design
Number
A16
(15.8 cm
3
/rev)
F: Flange Mtg.
L: Foot Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
04:
Proportional
Electro-Hydraulic
Load Sensing
Type
B: 1.5 - 6.9 (220 - 1000)
C: 1.5 - 15.7 (220 - 2280)
H: 1.5 - 20.6 (220 - 2990)
K: Keyed Shaft
32
A22
(22.2 cm
3
/rev)
B: 1.5 - 6.9 (220 - 1000)
C: 1.5 - 15.7 (220 - 2280)
32
A37
(36.9 cm
3
/rev)
B: 2 - 6.9 (290 - 1000)
C: 2 - 15.7 (290 - 2280)
H: 2 - 20.6 (290 - 2990)
32
A56
(56.2 cm
3
/rev)
32
A70 -F R 04 C S -60
Series Number Mounting
Direction of
Rotation
Control Type Pressure Adj. Range MPa Port Position
Design
Number
A70
(70.0 cm
3
/rev)
F: Flange Mtg.
L: Foot Mtg.
(
Viewed from
)
Shaft End
R: Clockwise
★1
04:
Proportional
Electro-Hydraulic
Load Sensing
Type
C: 1.5 - 16 (220 - 2320)
H: 1.5 - 21 (220 - 3050)
S: Side Port
60
A90
(91.0 cm
3
/rev)
60
A145
(145 cm
3
/rev)
60
1. Available to supply pump with anti-clockwise rotation. Consult Yuken for details.
2. Please inquire for A220 separatery.
63
PISTON PUMPS
A Series
A
Series Variable Displacement Piston Pumps
Proportional Electro-Hydraulic Load Sensing Type
Pipe Flange Kits
Pipe flange kits are available. When ordering, specify the kit number from the table below.
1. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of
the flanges. Therefore, please pay cautious attension to the operating pressure when the socket welding flanges are used.
2. Discharge port for pump model "A16" and "A22" is available only the threaded connections.
Details of the pipe flange kits are shown on page 262.
Pump Model Numbers Name of Port
Pipe Flange Kit Numbers
Threaded Connection Socket Welding
★1
Butt Welding
A16--R-04
A22--R-04
Suction F5-06-A-10 F5-06-B-10 F5-06-C-10
Discharge
★2
★2
★2
A37--R-04
A56--R-04
Suction F5-10-A-10 F5-10-B-10 F5-10-C-10
Discharge F5-06-A-10 F5-06-B-10 F5-06-C-10
A 70-R04
Suction F5-12-A-10 F5-12-B-10 F5-12-C-10
Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10
A 90-R04
A145-R04
Suction F5-16-A-10 F5-16-B-10 F5-16-C-10
Discharge F5-10-A-10 F5-10-B-10 F5-10-C-10
Instructions
Bleeding Air
In order to get steadily controlled pressure and flow, bleed air by loosening the air vent screw and fill solenoid armature with
operating oil.
Manual Adjustment Screws
Manual adjustment screws may be used for initial running adjustment or in case of electrical failures in order to adjust pressure
and flow temporarily. In case of normal use, put the manual adjustment screws back in their preset positions.
Position of Cable Departure
Position of cable departure can be changed. For details, refer to drawing below.
Connection of Surge Cut-off Valve to "A" Series Pump (For A16 to A56 Type)
If using surge cut-off valve (SF1105-A-10), connect between pilot port "PP" of this pump and port "PP" of surge cut-off valve as
pilot piping (refer to symbol below).
Inside diameter of pipe should be more than 8 mm.
Consult Yuken of detail of surge cut-off valve.
M
O
i1
i2
"PP"
Surge Cut-off Valve
(SF1105-A-10)
Connector
(The direction can be altered