13 SWS Software 2.1 Features
The SWS software 2.1 includes all functions from the SWS software 2.0. The following section
describes the main new features in version 2.1 of the SWS software.
NOTE
For details about the individual functions, please refer to the software manual for
the "SIPLACE SWS Software 2.1 [item no.: 00195986-02].
13.1.1 Revised Interface to Wafer Map Server
The menu navigation at Manual setting => Wafer-Map has been simplified. The settings and
monitoring options have been revised.
The option Connection settings => SIPLACE Wafer System has been extended. The software
now also supports passive connections to the wafer map server.

SIPLACE SWS Software 2.1 /
Versionsbeschreibung / Version Description Ausgabe 05/2014 Edition
30
13.1.2 Simplified Navigation in Manual Setting Menu
The menu navigation at Manual setting => Parameter test camera and in the corresponding
Wafer camera and Inspection camera views has been simplified.
A few unnecessary functions, such as Pattern Teaching, have been removed.

SIPLACE SWS Software 2.1 /
Versionsbeschreibung / Version Description Ausgabe Fehler! Unbekannter Name für Dokument-
Eigens
31
14 Errors Fixed
The following table contains a selection of errors which have been fixed in version 2.1:
Error code
Error description
D1-71690101
D1-96484758
The SWS sporadically stopped the production run for no apparent reason.
D16974-2804
In multi-die mode, one or more wafer maps are not reported back to the wafer
server on magazine changeover (sporadic error).
D16974-2668
While referencing partially processed wafers with the wafer map, there is a
sporadic error in which the processing path cannot be successfully calculated.
D1-97123701
Error refilling the wafers which were previously reported as empty to the station
software version 7.0x.
D1-97893212
In the Process menu of the GUI, incorrect magazine rack numbers are shown
for the wafer loaded or the wafer to be edited.
D1-97893262
The camera image is not refreshed in the GUI.