00194585-05_Installation_Manual_EDM_EN.pdf - 第30页

Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006 the master server ( 5.2.3.17 ) useModifiedObjectProtection String (“true”/”false”) L;D Forced overwriting of changed objects with older master data ( 5.2.3.1…

100%1 / 65
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
masterServer String L;M;C;R Network identification of the master
server (5.2.3.7)
notificationDistributorClass Class M;D Class for external notifications (e.g.
email) (5.2.3.3)
notificationDistributorConfiguratorClass Class M;D Configuration for external
notification system (e.g. email)
(5.2.3.4)
notificationInterval Time L;D Time to transfer the change
notification to the master (5.2.3.5)
notificationStorage Endpoint L;D Buffer for change notifications
(5.2.3.6)
responseTimeout Time L;D Timeout for replies from the master
(5.2.3.19)
requestCommandConfig Section M;R Scope of functionality of master
server (5.2.3.30)
serverType Enum L;M;C;R Operating mode of the installation
(5.2.3.1)
serviceRemotingEndpoint String L;R .NET remoting configuration for
communication with the line service
(5.2.3.22)
spiLines Section L SPI lines associated with this line
server. (5.2.3.24)
startingPoints Section M List of permissible object types for
starting points (5.2.3.28)
sqlDataSource String C;M;R SQL Server access for the clearing
pool (5.2.3.24)
sqlUserName String C;M;R User name for SQL Server access
(5.2.3.26)
sqlUserPassword String C;M;R Password for SQL Server access
(5.2.3.27)
templateStorage Path L;M;D Storage location for application
templates (5.2.3.23)
transceiverClass Class L;M;C;T;
D
Class of data transfer (5.2.3.8)
useAdvancedNotificationFiltering String
(“true”/”false”)
M;D Activate/deactivate direct
import/rejection of notifications in
29 of 65
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
the master server (5.2.3.17)
useModifiedObjectProtection String
(“true”/”false”)
L;D Forced overwriting of changed
objects with older master data
(5.2.3.18)
useBlobExtension String
(“true”/”false”)
L;M;D Activates/deactivates EDM VDM
blob extensions (5.2.3.32)
xmlImportVisionDataAdvancedAction Integer L;M;C;D Sets the
VisionDataAdvancedAction
property of XmlImport.
Table 7 Contents of the configuration file
5.2.3.1 Server type
Key: serverType
Enum Type:
Values: LINE
MASTER
BOTH
CLEARINGPOOL
Valid for: Line server
Master server
Clearing pool
Specifies the type of installation. The EDM server is started as a line server, master
server or hybrid depending on this setting (should only be used for test purposes).
Description:
5.2.3.2 Help directory
Key: helpDirectory
Path Type:
[AppDir]\help
Default:
Valid for: Line server
Master server
Clearing pool
EDM Tool
Directory for online documentation Description:
30 of 65
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
5.2.3.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Master server Valid for:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
Description:
5.2.3.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Class Type:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Default:
Master server Valid for:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
Description:
5.2.3.5 Notification interval
Key: notificationInterval
Time Type:
P0Y0M0DT0H15M0S (= 15 minutes)
Default:
Line server Valid for:
Description: Time period during which the change notifications will be collected on the line
servers before they are sent to the master server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
31 of 65