00194585-05_Installation_Manual_EDM_EN.pdf - 第32页
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006 The period should not be shorter than 5 minutes. 5.2.3.6 Notification storage Key: notificationStorage Endpoint Type: notificationStorage Default: Line serve…
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
5.2.3.3 Distribution list for EDM notifications
Key: notificationDistributorClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Master server Valid for:
Class, i.e. implementation of the notification service. At the present, distribution via
email is available using the default value as a reference.
Description:
5.2.3.4 Configuration of EDM notification traffic
Key: notificationDistributorConfiguratorClass
Class Type:
Siemens.SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Default:
Master server Valid for:
Configuration dialog box for the notification service. The actual configuration of the
notification service depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
Description:
5.2.3.5 Notification interval
Key: notificationInterval
Time Type:
P0Y0M0DT0H15M0S (= 15 minutes)
Default:
Line server Valid for:
Description: Time period during which the change notifications will be collected on the line
servers before they are sent to the master server. The other options are as
follows (from left to right):
Y = years
M = months
D = days
H = hours
M = minutes
S = seconds
31 of 65
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key: notificationStorage
Endpoint Type:
notificationStorage
Default:
Line server Valid for:
Buffer for collected change notifications. Description:
5.2.3.7 Master server
Key: masterServer
String Type:
Valid for: Line server
Master server
Clearing pool
Network ID of the master server. Windows computer name only. IP addresses are
not permitted.
Description:
5.2.3.8 Transceiver
Key: transceiverClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for: Line server
Master server
Clearing pool
EDM Tool
Implements the data transfer between the line servers and master server. This entry
must be identical on all installed systems. The exact format of the “endpoint” values
depend on this value. The default setting uses MSMQ to transfer the data.
Description:
Endpoint: An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can be
32 of 65
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
used in both a domain/active directory-based network environment as well as in a
pure workgroup installation.
5.2.3.9 Outgoing requests
Key: masterRequests
Endpoint Type:
Valid for: Line server
Clearing pool
Target address for service requests sent by a line server to the master server. The
setting must be identical to the “Incoming Requests” setting on the master server.
Description:
5.2.3.10 Outgoing change notifications
Key: masterNotifications
Endpoint Type:
Line server Valid for:
Target address for change notifications sent by a line server to the master server.
The setting must be identical to the “incoming change notifications” setting on the
master server.
Description:
5.2.3.11 Incoming requests
Key: incomingRequests
Endpoint Type:
Master server Valid for:
Description: Endpoint at which the master server listens in for incoming service requests.
Determines the value for “outgoing requests” on the line servers.
The value must be different from the value for “incoming change notifications”.
5.2.3.12 Incoming change notifications
Key: incomingNotifications
Endpoint Type:
33 of 65