00194585-05_Installation_Manual_EDM_EN.pdf - 第33页

Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006 used in both a domain/active directory-based network environment as well as in a pure workgroup installation. 5.2.3.9 Outgoing requests Key: masterRequests En…

100%1 / 65
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
The period should not be shorter than 5 minutes.
5.2.3.6 Notification storage
Key: notificationStorage
Endpoint Type:
notificationStorage
Default:
Line server Valid for:
Buffer for collected change notifications. Description:
5.2.3.7 Master server
Key: masterServer
String Type:
Valid for: Line server
Master server
Clearing pool
Network ID of the master server. Windows computer name only. IP addresses are
not permitted.
Description:
5.2.3.8 Transceiver
Key: transceiverClass
Class Type:
Default:
Siemens.SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for: Line server
Master server
Clearing pool
EDM Tool
Implements the data transfer between the line servers and master server. This entry
must be identical on all installed systems. The exact format of the “endpoint” values
depend on this value. The default setting uses MSMQ to transfer the data.
Description:
Endpoint: An endpoint entry has the following format for the MSMQ transceiver:
Private$\[queue-name].
Note that private queues absolutely must be used here. Only private queues can be
32 of 65
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
used in both a domain/active directory-based network environment as well as in a
pure workgroup installation.
5.2.3.9 Outgoing requests
Key: masterRequests
Endpoint Type:
Valid for: Line server
Clearing pool
Target address for service requests sent by a line server to the master server. The
setting must be identical to the “Incoming Requests” setting on the master server.
Description:
5.2.3.10 Outgoing change notifications
Key: masterNotifications
Endpoint Type:
Line server Valid for:
Target address for change notifications sent by a line server to the master server.
The setting must be identical to the “incoming change notifications” setting on the
master server.
Description:
5.2.3.11 Incoming requests
Key: incomingRequests
Endpoint Type:
Master server Valid for:
Description: Endpoint at which the master server listens in for incoming service requests.
Determines the value for “outgoing requests” on the line servers.
The value must be different from the value for “incoming change notifications”.
5.2.3.12 Incoming change notifications
Key: incomingNotifications
Endpoint Type:
33 of 65
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
Master server Valid for:
Description: Endpoint at which the master server listens in for incoming change notifications.
Determines the value for “outgoing change notifications” on the line servers.
The value must be different from the value for “incoming requests”.
5.2.3.13 Incoming clearing pool requests
Key: incomingClearingPoolRequests
Endpoint Type:
Valid for: Master server
Clearing pool
Endpoint at which the clearing pool listens for incoming commands from the master
service.
Description:
5.2.3.14 EDM tool endpoint
Key: edmToolEndPoint
Endpoint Type:
EDM_SPI_REMOTE_HOST:9002/EdmTool
Default:
Valid for: Master server
Line server
EDM Tool
Description: Endpoint for entering change notifications. The default value means that the
comment dialog boxes always open on the computer at which the SPI event
was triggered that caused the notification which requires a comment (if an EDM
tool is installed there).
If the line engineer is to enter the comments at a different computer, replace
EDM_SPI_REMOTE_HOST in the configuration file of the line server with the
host name of this computer.
5.2.3.15 Endpoint configuration
Key: endpointConfig
Section Type:
34 of 65