00194585-05_Installation_Manual_EDM_EN.pdf - 第39页
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006 5.2.3.26 SQL user name Key: sqlUserName String Type: Valid for: Master server Clearing pool User name for access to the SQL server. Description: 5.2.3.27 SQL …
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
Line server Valid for:
Description: .NET remoting endpoint for communication between the EDM client and EDM line
server. The entry has the format:
[servername]:[tcpport]/EdmService
5.2.3.23 Application template storage
Key: templateStorage
Path Type:
[AppDir]\templateStorage
Default:
Valid for: Line server
Master server
Storage location for application templates. The path can be specified absolutely or
relative to the EDM installation directory.
Description:
5.2.3.24 Assigned SPI lines
Key: spiLines
Section Type:
Line server Valid for:
Description: Contains the SPI lines assigned to the line server. This entry is only used for
the EDM VDM blob extensions.
The entries have the format <line path="path"/>, where “path” is the
unqualified full path of the line.
5.2.3.25 SQL database access
Key: sqlDataSource
String Type:
Valid for: Master server
Clearing pool
Description: Access to the SQL server to store the change notifications and the objects changed
on the lines (EDM database).
This setting does not refer to the SIPLACE Pro database.
38 of 65
Installation Manual SIPLACE EDM Version 1.1 SP2 Issue 12/2006
5.2.3.26 SQL user name
Key: sqlUserName
String Type:
Valid for: Master server
Clearing pool
User name for access to the SQL server. Description:
5.2.3.27 SQL password
Key: sqlUserPassword
String Type:
Valid for: Master server
Clearing pool
Password for access to the SQL server. Description:
5.2.3.28 Starting point
Key: startingPoints
Section Type:
Master server Valid for:
Description: Configures allowable starting points in the application template.
The entry has the format
<objectServerType value=“ObjectServerType”/>
5.2.3.29 Comment categories
Key: CommentCategories
Section Type:
Valid for: Master server
EDM Tool
Description: The entry has the format
<category value=“category”/>
39 of 65
Installation Manual, SIPLACE EDM Version 1.1 SP2 Issue 12/2006
5.2.3.30 Request configuration
Key: requestCommandConfig
Section Type:
Master server Valid for:
Description: This section contains pairs of values of the form:
<add key="[request]" value="[Class]"/>
There is one entry for each of the services provided by the master server. These
settings should only be changed by the developer since they depend on the
implementation of the master server, and improper settings can affect the integrity
and operation of the system as a whole.
See SDS SIPLACE EDM.
5.2.3.31 Aliases
Key: machineAliasNames
Section Type:
Valid for: Line server
Master server
Clearing pool
Description: The network ID of EDM computers is converted to an alias when it is displayed in
the EDM program components in order to make it more readable for humans. Enter
all the line servers in the overall EDM system in this section. This section contains
pairs of values of the form:
<add key="[string]" value="[string]"/>
The key is the network identification of an EDM computer (not an IP address, only
Windows computer names). The value can be any name different from the network
ID.
Important note: The assignment of the computer ID to the alias must be identical on
all EDM computers (master server, line server, clearing pool).
5.2.3.32 EDM 1.1 VDM blob extensions
Key: useVdmExtension
String Type:
true
Default:
40 of 65