TP2492.Parts Set Pos Quantity Arrangement.pdf - 第11页

  SMT Software Engineering Group IM Operati ons YAMAHA MOTOR CO., LTD. MDO C-SOFT502 34  11 /18 Fig.8. [Add] button to register setting recor d Fig. 9. [A dd setting] window

100%1 / 18
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50234 10/18
Fig. 7. Display the setting from Optimizer Setting
4.2.2.2 The way to add the setting
1. Click [Add] button (*8)
The setting records which are shown in “Setting of parts set pos quantity by same
parts” differ depending on from what window it is started. Their parts are exit in the
board data which are registered to the lists as shown in sheet 2.
(*8) When there are no parts to newly add, the button is gray out.
Add board data to “List op optimizations” in the Optimizer or to the Plan in the Feeder
Viewer.
Sheet 2. Target Board Data
StartWindow TargetBoardData ReferenceFigure
FeederViewer Plan Fig.4
Optimizer Listofoptimizations Fig.5
Setoptimizationparameters Listofoptimizations Fig.6
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50234 11/18
Fig.8. [Add] button to register setting record
Fig. 9. [Add setting] window
SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD.
MDOC-SOFT50234 12/18
2. Click the cell in the left side of parts list. (To select plural parts, drug them.)
Fig. 10. Select parts
3. Select the parameters in [Dual Lane] and [Each Lane] in the right area of the “Add
setting”.
Fig. 11. Select parameter