GEM for SIPLACE V7.01 Page 10 of 251 ©Siemens AG, all rights reserved FiducialNum ber Level, DataValid, Gantr y GroupId, Gantr y Id, HeadId, Segm ent, CompPic kedUp, Com pLef t2Place and Com pPlaced inf orm ation chan…

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 9 of 251
,QWURGXFWLRQ
This document describes the SECS interface version 405.xx provided on the SIPLACE.
Changes from Host Interface Manual V2.0:
• Section 4.2: Documentation of Data Items corrected: PickUpResult, PlacementResult
• Section 4.9: Documentation corrected: PPBODY is a binary data block
• Section 6: Documentation corrected: PICKUPERRORS (VID 2012019)
• Section 8: New Collection Events: PCBstartProcessing (CEID 2010013),
MachineReStarted (CEID 2010015)
Changes from Host Interface Manual V3.01:
• Section 4.2: Documentation of Data Items corrected.
• Section 6: New Variables: COMPONENTBARCODE (VID 912003),
WAYOFINPUTCOMPONENTBARCODE (VID 912004), MACHINESIDE (VID
2012022), TRACKNUMBER (VID 2012023), DIVISION (VID 2012024), LEVEL (VID
2012025), SEGMENT (VID 2012026), COMPONENTNAME (VID 2012027),
GANTRYID (VID 2012028), GROUPGANTRYID (VID 2012029), HEADID (VID
2012030), REFERENCEDESIGNATOR (VID 2012031), PACKAGEFORMNUMBER
(VID 2012032), PLACEERRORDESCPIPTION (VID 2012033),
GEMTIMEFORMAT(VID 1002065)
Variable TIME (VID 1002023) changed
• Section 6: Documentation corrected: PLACEINFOREV1 (VID 1312004),
PLACEINFOREV2 (VID 1412003), PLACEINFOIC (VID 1512014) and oder of VID’s
corrected.
• Section 7: New Predefined Reports: BeBarcode(RPTID 27), PickUpError (RPTID 28),
PlaceError (RPTID 29)
• Section 8: New Collection Event: ComponentBCread (CEID 920002), PickUpError
(CEID 2010016), PlaceError (CEID 2010017)
Changes from Host Interface Manual V3.02:
• The default spooling state is now “not spooling”.
• Section 4.2: Documentation of Data Items corrected.
• Section 6: Order of the Variables corrected. New Variables:
PCBSIDEININPUTCONVEYOR(VID 921005), PCBSIDEINCENTERCONVEYOR
(VID 921006), BCINTWINCENTERCONVEYOR (VID 912011),
BCINTWININPUTCONVEYOR (VID 912012), PCBSIDEINTWININPUTCONVEYOR
(VID 921015), PCBSIDEINTWINCENTERCONVEYOR (VID 921016),
BCREADEREXIST (VID 912017)
Names of Variables corrected: TRANSPORTWIDTH, GANTRYONERROR
(correction in manual)
GUINOZZLETYPE VID corrected to 11220006 (correction in manual)
STIME format corrected in this manual: S6F1 description
• Section 7: New Predefined Reports: BarcodeTwin (RPTID 30)
• Section 8: New Collection Event: FM_WAG_KEIN_BE_ENTSORG (CEID 1711016),
BCTwinRead (CEID 920011)
Changes from Host Interface Manual V5.01 Standard
• Name of data item corrected : ComPickedUp to CompPickedUp
• Section 4.2: NewData Items PickErrors, PlaceErrors.

GEM for SIPLACE V7.01
Page 10 of 251 ©Siemens AG, all rights reserved
FiducialNumberLevel, DataValid, GantryGroupId, GantryId, HeadId, Segment,
CompPickedUp, CompLeft2Place and CompPlaced information changed and added.
• Section 6: New Variables:
VID 1312008 PLACEINFOREV1SUB1, VID 1412008 PLACEINFOREV2SUB1
VID 1312007 SEGMENTINFOREV1, VID 1412007 SEGMENTINFOREV2, VID 1512016
SEGMENTINFOIC
VID 1002068 NICKNAME
VID 1002069 LASTERRORCODE,
VID 1002070 LASTFMTEXT (for event FM_GENERAL)
• Section 6: Corrections
VID 1002043 SPOOLSTATE,
VID 412001 TAUGHTFIDUCIAL,
VID 412002 FIDUCIALDATA,
VID 2012013 ERRORTYPE,
VID 912004 WAYOFINPUTCOMPONENTBARCODE,
VID 912005 PCBSIDEININPUTCONVEYOR,
VID 912006 PCBSIDEINCENTERCONVEYOR,
VID 2012016 TRACKONERROR,
VID 1002054 SOFTWAREREVTABLE
• Section 7: New Report:
RPTID 44 FM_GENERAL,
RPTID 46 TrackEmpty/TrackFull,
RPTID 47 Transport2
• Section 8: New Section “Other Error-Events” inserted
• Section 8: Corrections and Changes:
CEID 1120238 ToGUISitestStarted,
CEID 1120239 ToGUISieTestFinished,
CEID 1120248 GUIReqSietestStart,
CEID 1120257 RepGUIReqSietestStart,
CEID 2010016 PickUpError
• Section 8: New Error Collection Event:
CEID 121049 FM_AS_FALSCHE_MCVERSION,
CEID 211048 FM_PIP_KONV_NOK,
CEID 311297 FM_D_IC_KLEMMT_REF,
CEID 511161 FM_OPT_SPURLEER,
CEID 511162 FM_VS_DATA_ANF_DSV,
CEID 511163 FM_VS_SYSTEM,
CEID 1001024 FM_GENERAL,
CEID 1211080 FM_CAN_MSG_Z_ACHSE_OB_IC,
CEID 1211081 FM_CAN_MSG_BESTUECKEN_SP,
CEID 1711026 FM_WAG_RIO,
CEID 2211001 FM_ABH_KEIN_BE,
CEID 2211002 FM_BEST_KEIN_BE,
CEID 2211003 FM_ABH_SPURLEER,
CEID 2211004 FM_FM_SPURLEER,
CEID 2211006 FM_VAK_DELTA_GRENZE_SP,
CEID 2211032 FM_BA_NOTAUS,
CEID 2211033 FM_SP_COM_ERR,
CEID 2211034 FM_SP_CONFIG,
CEID 2211035 FM_SIPLPRO_GF_STORE_NOK,
CEID 2211036 FM_SIPLPRO_MK_STORE_NOK,
CEID 2211037 FM_SP_2SERVER,
CEID 2211038 FM_NUTZEN_OHNE_MARKE,

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 11 of 251
CEID 2211039 FM_BA_SCHUETZ_K5,
CEID 2211040 FM_BA_DRUCKLUFT,
CEID 2211041 FM_TRANSP_MA,
CEID 2211042 FM_FK_TRACK_RUN_LOW_MIN,
CEID 2211043 FM_FK_TRACK_RUN_LOW_PERCENT,
CEID 2211044 FM_FK_TRACK_RUN_LOW_VALUE,
CEID 2211045 FM_SPUR_LEER_FK
• Section 8: Removed Error Collection Event:
CEID 121032 FM_GK_MA_DAT,
CEID 121033 FM_GK_RU_DAT,
CEID 121034 FM_GK_NU_DAT,
CEID 121035 FM_GK_MK_DAT,
CEID 121036 FM_GK_GF_DAT,
CEID 311296 FM_MOT_JUSTAGE_NOT_OK
The SEMI Equipment Communication Standard (SECS) is published by Semiconductor
Equipment and Materials International (SEMI). It defines a computer to computer
communications interface between a unit of factory Equipment and a Host Computer.
This Equipment complies to the SECS-II standard, all SECS-II message used in GEM are
implemented. The SIPLACE complies to the following versions of standards:
E5-1994 (SECS-II)
SEMI Document #2758, Line 1 Item #1 (The Year 2000 issue)
6(&6,,&ODULILFDWLRQV
SIPLACE GEM is Year 2000 compliant according to the new Year 2000 SECS-II Standard
(SEMI Document #2758, Line 1 Item #1).
The SIPLACE uses the following SECS-II conventions:
'DWD)RUPDW7\SHV
Where the Standards permit a choice of data item types, the choice has been made as
described in section „Message Detail“.
For outgoing messages, the Equipment always sends Data Items of the exact format
shown. For some incoming messages, the Equipment „forgives“ minor host errors. For
example, the Equipment may accept a U1 Data Item where a U2 format was expected.
We recommend the Host attempt to use the formats shown.
'DWD,WHP/HQJWK%\WHV
For messages sent by the Equipment, the number of length bytes in Data Items is always
the minimum required to contain the Data Item length.
For messages received from the Host, the number of length bytes in Data Items can be 1,
2, or 3, provided that the length parameter can accurately be specified.
$6&,,'DWD
Unless otherwise specified, all ASCII data items must contain printable ASCII data—that
is, characters in the range 0x20 to 0x7E.
0XOWL%ORFN0HVVDJHV
Wherever the Host is supposed to send a single-block message, this Equipment will also
accept multi-block format.
The maximum size for a single SECS message is approximately 1000 blocks (256,000
bytes).