00192402-01.pdf - 第145页
GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 145 of 251 3URFHVV3URJUDP 8QIRUPDWWHG +RVW,QLWLDWHG Step SECS Mes sage Descri ptio n 1. H - > E S7F1 W Host reques ts perm ission to s end a…

GEM for SIPLACE V7.01
Page 144 of 251 ©Siemens AG, all rights reserved
2SHUDWRU&RPPDQG6XFFHVVIXO
Step SECS Message Description
1. ControlState is Local. The operator issues a
front-panel INITIATE PROCESS command. The
Equipment performs the command.
2. H <- E S6F11 W The Equipment signals CEID LotStart. Event
Reports as appropriate.
3. H -> E S6F12 The Host acknowledges the report.

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 145 of 251
3URFHVV3URJUDP
8QIRUPDWWHG+RVW,QLWLDWHG
Step SECS Message Description
1. H -> E S7F1 W Host requests permission to send a multi-block
Process Program to the Equipment. If the
Process Program is single-block, this step and
the next one may be skipped.
2. H <- E S7F2 The Equipment grants permission for the Host to
send the Process Program.
3. H -> E S7F3 W Host sends the process Program to the
Equipment.
4. H <- E S7F4 The Equipment acknowledges receipt of the
Process Program. The Equipment checks the
received Process Program for validity. If the
process Program is valid, the Equipment stores
the Process Program in its library and sends an
acknowledge code of zero in this message. If
the Process Program is not valid, or could not be
stored in the library, the acknowledge code in
this message is non-zero.
8QIRUPDWWHG+RVW,QLWLDWHG
Step SECS Message Description
1. H -> E S7F5 W Host requests a Process Program from the
Equipment library.
2. H <- E S7F5 The Equipment sends the Process Program. If
the Process Program does not exist, the data
portion of this message is an empty list.
8QIRUPDWWHG(TXLSPHQW,QLWLDWHG
Step SECS Message Description
1. H <- E S7F5 W Equipment requests a Process Program.
2. H -> E S7F6 The Host sends the Process Program. If the
Process Program is valid, the Equipment stores
the Process Program in its library, and the
scenario ends. If the data portion of S7F6 is an
empty list, or if the Process Program is not valid,
the Equipment does not store it in its library and
the scenario continues.
3. H <- E S6F11 W The Equipment sets „PPCHANGENAME“ to the
requested PPID and signals CEID
GemBadDownloadEvent. Event reports as
appropriate.
4. H -> E S6F12 The Host acknowledges the report.

GEM for SIPLACE V7.01
Page 146 of 251 ©Siemens AG, all rights reserved
8QIRUPDWWHG(TXLSPHQW,QLWLDWHG
Step SECS Message Description
1. H <- E S7F1 W Process Program Inquire. If S7F3 is multi-block,
the Equipment requests permission to send a
multi-block message. If S7F3 is single-block,
skip this and the following step.
2. H -> E S7F2 Process Program Grant. The Host grants
permission. If PPGNT is non-zero, the scenario
fails here.
3. H <- E S7F3 W Send Process Program. The Equipment
uploads Process Program to Host.
4. H -> E S7F4 The Host acknowledges. The Equipment
ignores ACKC7.
+RVW'HOHWHV3URFHVV
Step SECS Message Description
1. H -> E S7F17 W Host sends a request to delete one or more
Process Programs from the Equipment’s library
of Process Programs.
2. H <- E S7F18 The Equipment replies with an acknowledge
code. If all specified Process Program(s) were
deleted successfully, the acknowledge code is 0.
If one or more of the specified Process
Programs could not be deleted, the acknowledge
code is non-zero.
+RVW5HTXHVWV'LUHFWRU\
Step SECS Message Description
1. H -> E S7F19 W Host requests the names (PPIDs) of all Process
Programs that are stored in the Equipment’s
Process Program library.
2. H <- E S7F20 The Equipment replies with the list of PPIDs.