00192402-01.pdf - 第198页

GEM for SIPLACE V7.01 Page 198 of 251 ©Siemens AG, all rights r eserved CEID Name De scripti on 211014 FM_PW _SP_KONF_NOK Nozzle ty pe not available in c hanger m agazine SP* 1 211015 FM_PW _SP_ANZ_GAR_LEER Not enouph ga…

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 197 of 251
specified in configuration*
111090 FM_BLASDRUCK_ZU_GERING RV head: Air kiss pressure during
placement too low*
1
111091 FM_BLASDRUCK_ZU_HOCH RV head: Air kiss pressure during
placement too high*
1
111092 FM_GK_SR_STAND_ALONE Communication problem with LC,
station switched to 'Stand alone'*
1
111093 FM_MAP_MESSD_FEHLT MP_MESS.DAT mapping file not
available*
1
111094 FM_MAP_MESSD_NR_FALSCH Faulty number in MP_MESS.DAT
mapping file*
1
111095 FM_MAP_MESSD_INDEX Bad access to MP_MESS.DAT file* 1
111096 FM_MAP_DAT_KOMM Task mapping data: communications
error*
1
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these software
collection events.
1R]]OH&KDQJHU
CEID Name Description
211001 FM_PW_IC_OPTION IC head nozzle-changer option not
set*
1
211002 FM_PW_IC_PIPTYP Nozzle type not available* 1
211003 FM_PW_IC_RUESTUNG Nozzle type not in IC head nozzle-
changer set-up*
1
211004 FM_PW_IC_PIP_VORH Nozzle available on IC head* 1
211005 FM_PW_IC_ABW_D_ABH Deviation in d axis rotation at IC head
nozzle pick-up*
1
211006 FM_PW_IC_ABW_D_ABL Deviation in d axis rotation at IC head
nozzle return*
1
211007 FM_PW_IC_Z_SOLLPO_UEB_
ABH
Required Z-axis position exceeded
during IC nozzle pick-up*
1
211008 FM_PW_IC_Z_SOLLPO_N_ER
_ABH
Required Z-axis position exceeded
during IC nozzle pick-up*
1
211009 FM_PW_IC_Z_SOLLPO_UEB_
ABL
Required Z-axis position exceeded at
IC nozzle return*
1
211010 FM_PW_IC_Z_SOLLPO_N_ER
_ABL
Required Z-axis position not reached
at IC nozzle return*
1
211011 FM_PW_IC_NO_PIP Nozzle not available at nozzle changer
IC head*
1
211012 FM_PW_IC_UMRUESTEN Modify nozzle changer IC head* 1
211013 FM_PW_SP_UMRUESTEN Modify Revolver head nozzle-changer* 1
GEM for SIPLACE V7.01
Page 198 of 251 ©Siemens AG, all rights reserved
CEID Name Description
211014 FM_PW_SP_KONF_NOK Nozzle type not available in changer
magazine SP*
1
211015 FM_PW_SP_ANZ_GAR_LEER Not enouph garages in changer
magazine for nozzle return. SP*
1
211016 FM_PW_SP_ANZ_GAR_VOLL Insuff. number of nozzles in changer
magazine SP to pick up*
1
211017 FM_PW_SP_KEIN_NUTZEN No cluster available for nozzle pick-up
SP*
1
211018 FM_PW_SP_MODUL_ENTR_N
OK
Nozzle-changer revolver head cannot
be unlocked*
1
211019 FM_PW_SP_MODUL_VERR_N
OK
Nozzle-changer revolver head cannot
be locked*
1
211020 FM_PW_SP_VISION_KOM_NO
K
Communication with Vision System
during nozzle check disturbed*
1
211030 FM_PW_SP_ABH_NOK Nozzle SP pick-up not completed* 1
211031 FM_PW_SP_ABW_NOK Nozzle return SP not completed* 1
211032 FM_PW_SP_Z_SOLLPO_UEB_
ABH
Required Z-axis position exceeded
during SP nozzle pick-up*
1
211033 FM_PW_SP_Z_SOLLPO_N_ER
_ABH
Required Z-axis position not reached
during SP nozzle pick-up*
1
211034 FM_PW_SP_Z_SOLLPO_UEB_
ABL
Required Z-axis position exceeded at
SP nozzle return*
1
211035 FM_PW_SP_Z_SOLLPO_N_ER
_ABL
Required Z-axis position not reached
at SP nozzle return*
1
211036 FM_PW_SP_Z_SOLLPO_UEB_
ABW
Required Z axis position exceeded at
SP nozzle ejection*
1
211037 FM_PW_SP_Z_SOLLPO_N_ER
_ABW
Required Z axis position not reached
at SP nozzle ejection*
1
211038 FM_PW_SP_ABL_NOK_ALLG_
F
Nozzle not returned to
<magazine/garage>:*
1
211039 FM_PW_SP_ABH_NOK_ALLG_
F
Nozzle not picked up from
<magazine/garage>:*
1
211040 FM_PW_SP_ANZ_GAR_VOLL_
ALLG_F
Nozzle type not available <type/for
segment>:*
1
211041 FM_PW_SP_ANZ_GAR_LEER_
ALLG_F
Nozzle type not returnable <type/from
segment>:*
1
211042 FM_HOEH_PIP_DL_ZU_GROS
S
Incorrect nozzle length* 1
211043 FM_PW_SP_PINOLE_GEZ segment removed. * 1
211044 FM_PW_STD_MA file PPW_STD.MA not found or
incorrect*
1
211045 FM_PW_VERM_MA file PPW_VERM.MA not found or
incorrect*
1
211046 FM_PW_AKT_MA file PPW_AKT.MA not found or
incorrect*
1
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 199 of 251
CEID Name Description
211047 FM_SCAN_PIP_VERSCHMUTZ
T
Nozzle contaminated or worn-out* 1
211048 FM_PIP_KONV_NOK New nozzle configuration is required 1
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these nozzle
changer collection events.
$[LV
CEID Name Description
311001 FM_ABH_PROXIMITY
SWITCH_OBEN
not defined 1
311002 FM_ABH_IC_PROXIMITY
SWITCH_OBEN
Undefined 1
311003 FM_Z_N_OBEN Z-axis cannot be moved upwards* 1
311004 FM_X_N_OBEN Undefined error message 1
311005 FM_Y_N_OBEN Undefined error message 1
311006 FM_S_N_OBEN Undefined error message 1
311007 FM_D_N_OBEN Undefined error message 1
311008 FM_DUMMY_ACHSE undefined 1
311009 FM_Z_IC_N_OBEN Z-axis on IC head cannot be moved
upwards*
1
311010 FM_D_IC_N_OBEN Undefined error message 1
311011 FM_X_PROG_FEHLER Programmed position of X-axis
outside travel range*
1
311012 FM_Y_PROG_FEHLER Programmed position of Y-axis
outside travel range*
1
311013 FM_D_PROG_FEHLER Programmed position of D1 axis
outside travel range*
1
311015 FM_S_PROG_FEHLER Programmed position of S-axis
outside travel range*
1
311016 FM_Z_PROG_FEHLER 75 Programmed position of Z-axis
outside travel range*
1
311017 FM_X_TOL_BIT Position control of X-axis does not
work*
1
311018 FM_Y_TOL_BIT Position control of Y-axis does not
work*
1
311019 FM_S_TOL_BIT Position control of S-axis does not
work*
1
311020 FM_Z_TOL_BIT Undefined error message 1
311021 FM_D_TOL_BIT Undefined error message 1