00192402-01.pdf - 第141页

GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 141 of 251  $ ODUP5HSRUW*(09HU&RPSDWL ELOLW\ Note: This scenario is provided only for com patibility w ith Host com puters which support G…

100%1 / 251
GEM for SIPLACE V7.01
Page 140 of 251 ©Siemens AG, all rights reserved
 $ODUPV
 (TXLSPHQW5HSRUWV$ODUP
Step SECS Message Description
1. H <- E S5F1 [W] If reporting for this alarm ID is disabled, skip this
and the following step. Otherwise send the
alarm. The Equipment Constant WBitS5
determines whether the W-bit is 0 or 1 in this
message.
2. H -> E S5F2 If the W-bit in S5F1 is 1, the Host acknowledges
the alarm report. Otherwise, skip this step.
3. H <- E S6F11 W If the event ID associated with this alarm state is
enabled, send the event report. Otherwise, the
scenario ends.
4. H -> E S6F12 The Host acknowledges the event report.
 +RVW(QDEOHV'LVDEOHV$ODUPV
Step SECS Message Description
1. H -> E S5F3 [W] The Host specifies ALIDs to be enabled or
disabled.
2. H <- E S5F4 If the W-bit in S5F3 is 1, the Equipment
acknowledges.
 +RVW5HTXHVWV$ODUPV
Step SECS Message Description
1. H -> E S5F5 W The Host requests whether specified ALIDs are
on or off.
2. H <- E S5F6 The Equipment sends Alarm status.
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 141 of 251
 $ODUP5HSRUW*(09HU&RPSDWLELOLW\
Note: This scenario is provided only for compatibility with Host computers which support
GEM, Ver 3.1.
Step SECS Message Description
1. The Equipment Constant ConfigAlarms is set to
2 for non-GEM compatibility.
The Equipment recognizes that an alarm
condition has gone on (i.e. has become
Unsafe).
2. H <- E S5F73 [W] The Equipment reports the Alarm going on. The
high-order bit of ALCD is 1.
3. H -> E S5F74 If the W-bit of S5F74 is 1, the Host
acknowledges the Alarm.
4. The Equipment recognizes that the alarm
condition has gone off (i.e. has become Safe).
5. H <- E S5F73 [W] The Equipment reports the Alarm going off. The
high-order bit of ALCD is 0.
6. H -> E S5F74 If the W-bit in S5F74 is 1, the host acknowledges
the Alarm.
 $ODUP5HSRUW*(09HU&RPSDWLELOLW\
Note: This scenario is provided only for compatibility with Host computers which support
GEM, Ver 1.7.
Step SECS Message Description
1. The Equipment Constant ConfigAlarms is set to
1 for GEM, Ver 1.7 compatibility.
The Equipment recognizes that an alarm
condition has gone on (i.e. has become
Unsafe).
2. H <- E S5F71 [W] The Equipment reports the Alarm going on. The
high-order bit of ALCD is 1.
3. H -> E S5F72 If the W-bit in S5F71 is 1, the Host
acknowledges the Alarm.
4. The Equipment recognizes that the alarm
condition has gone off (i.e. has become Safe).
5. H <- E S5F71 [W] The Equipment reports the Alarm going off. The
high-order bit of ALCD is 0.
6. H -> E S5F72 If the W-bit in S5F71 is 1, the Host
acknowledges the Alarm.
GEM for SIPLACE V7.01
Page 142 of 251 ©Siemens AG, all rights reserved
 &RQWURO6WDWH
 +RVW6HQGV2Q/LQH&RPPDQG
Assumption: Control State is "Host Off-Line". Variable GemControlState = 3.
Step SECS Message Description
1. H -> E S1F17 W Host instructs the Equipment to go On-Line.
2. H <- E S1F18 Equipment responds to successful On-Line
transition with ONLACK=0. Control state transits
to either Local or Remote as guided by EC
GemOnlineSubstate.
3. H <- E S6F11 W The Equipment signals CEID
GemControlState LOCAL or
GemControlState REMOTE.
4. H -> E S6F12 The Host acknowledges the event.
 +RVW6HQGV2II/LQH&RPPDQG
Assumption: Control State is "On-Line".
Step SECS Message Description
1. H -> E S1F15 W Host instructs the Equipment to go Off-Line.
2. H <- E S1F16 Equipment Control State transitions to Host
Off-Line (GemControlState = 3) and responds
to primary. OFLACK = 0.
 +RVW6HQGV5HPRWH&RPPDQG
Assumption: Control State is On-Line and Remote.
Step SECS Message Description
1. H -> E S2F41 [W] The Host sends the command. The W-bit in
this message bay be either 0 or 1.
2. H <- E S2F42 If the W-bit was 1, the Equipment
acknowledges the command. If the Equipment
cannot perform the command, the
acknowledge code in this message is non-zero.
If the command can be completed
immediately, the command is performed and
the acknowledge code in this message is 0.
Otherwise, if the command takes a significant
amount of time to complete, the acknowledge
code is 4. Successful completion of a
command may trigger one or more events.
 (TXLSPHQW5HMHFWV+RVW&RPPDQG
Assumption: Control State is Local and On-Line
Step SECS Message Description