GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 225 of 251 &(,' 1DPH 'HVFULSWLRQ 1120015 GUIPack ageForm Mess age from GU I: Entry package form m odif ication 1 1120016 GUIwithoutLCU Message f …

GEM for SIPLACE V7.01
Page 224 of 251 ©Siemens AG, all rights reserved
&(,' 1DPH 'HVFULSWLRQ
1001020 FM_GEM_INIT_GUI GEM: Error upon initialization of
interface to user interface*
1
1001021 FM_GEM_SIPLACE GEM: Error in SIPLACE GEM
software*
1
1001022 FM_GEM_OP_MELDUNG GEM: Most recent operator
message could not be sent to the
host*
1
1001023 FM_GEM_VERB_GUI GEM: Faulty connection between
GEM interface and user interface*
1
1001024 FM_GENERAL General Error Event
Error messages can be reported
either with specific error events (an
Error Event with a CEID for each
individual error) or with the General
Error Event that reports all errors.
The General Error Event has an
error code <LASTERRORCODE>,
which contains the CEID of the
specific Error Event.
The SV <LASTFMTEXT> which
contains the error text of the specific
Error Event is also available.
44
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these GEM-
kernel collection events.
2SHUDWRU
&(,' 1DPH 'HVFULSWLRQ
1120001 EmergencyStop Emergency stop pressed 1
1120002 StopButton Stop button pressed 1
1120003 StartButton Start button pressed 1
1120007 GUIStart Message from GUI: Start. 1
1120008 GUISTOP Message from GUI: Stop. 1
1120009 GUIContinue Message from GUI: Continue. 1
1120010 GUIAbort Message from GUI: Abort. 1
1120011 GUISingleFuncGan1 Message from GUI: Entry single
function gantry 1
1
1120012 GUISingleFuncGan2 Message from GUI: Entry single
function gantry 2
1
1120013 GUITransportFunc Message from GUI: Entry transport
function
1
1120014 GUIFiducialTeach Message from GUI: Entry fiducial
teaching
1

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 225 of 251
&(,' 1DPH 'HVFULSWLRQ
1120015 GUIPackageForm Message from GUI: Entry package
form modification
1
1120016 GUIwithoutLCU Message from GUI: Running without
LCU
1
1120017 GUILoadPP Message from GUI: Load Placement
Program
1
1120018 GUIPassThrough Message from GUI: PCB-Barcode
error „pass through“
1
1120019 GUIRemovePCB Message from GUI: PCB-Barcode
error „remove PCB“
1
1120020 GUIBCbyKeyboard Message from GUI: PCB-Barcode
entered by keyboard
1
1120021 GUIReqMaOption Message from GUI: Request machine
options
1
1120022 GUIReqMaConf Message from GUI: Request machine
configuration
1
1120023 GUISetMaOption Message from GUI: Set machine
options
1
1120024 GUISingleStepOn Message from GUI: Set single step
mode on
1
1120025 GUISingleStepOff Message from GUI: Set single step
mode off
1
1120026 GUITableProgDownload Message from GUI: Table program
download
1
1120027 GUIAllTrackRefill Message from GUI: Set all tracks
refilled and <GUITRACKNR> will be
updated
1
1120028 GUITrackRefill Message from GUI: Set
<GUITRACKNR> refilled
1
1120029 GUIFeederBankRefill Message from GUI: Set feeder bank
refilled and <GUITRACKNR> will be
updated
1
1120030 GUILinearFeederOn Message from GUI: Vibrate linear
feeders ON and <GUITRACKNR> will
be updated
1
1120031 GUILinearFeederOff Message from GUI: Vibrate linear
feeders OFF and <GUITRACKNR>
will be updated
1
1120032 GUIReqInvenWPC Message from GUI: Request WPC
inventory status and <GUITRACKNR>
will be updated
1
1120033 GUIReqMaxWPC Message from GUI: Request WPC
maximum fill stand and
<GUITRACKNR> will be updated
1
1120034 GUISetInvenWPC Message from GUI: Set WPC
inventory status and <GUITRACKNR>
will be updated
1

GEM for SIPLACE V7.01
Page 226 of 251 ©Siemens AG, all rights reserved
&(,' 1DPH 'HVFULSWLRQ
1120035 GUIReqConfWPC Message from GUI: Request WPC
configuration
1
1120036 GUIRefillPosWPC Message from GUI: WPC to refill
position
1
1120037 GUIContinueWPC Message from GUI: WPC continue
(leave refill position)
1
1120038 GUITransportWPC Message from GUI: WPC to transport
position
1
1120039 GUIRefRunWPC Message from GUI: WPC reference
run
1
1120040 GUIReqTrayWPC Message from GUI: WPC request tray 1
1120041 GUIImageGan1On Message from GUI: Image from
camera at gantry 1 ON
1
1120042 GUIImageGan1Off Message from GUI: Image from
camera at gantry 1 OFF
1
1120043 GUIImageGan2On Message from GUI: Image from
camera at gantry 2 ON
1
1120044 GUIImageGan2Off Message from GUI: Image from
camera at gantry 2 OFF
1
1120045 GUIRevolverStep Message from GUI: Step to next
revolver position and
<GUIGANTRYNR> will be updated
1
1120046 GUIRevPos1 Message from GUI: Revolver to
position 1 and <GUIGANTRYNR> will
be updated
1
1120047 GUIHeadRefRun Message from GUI: Head reference
run and <GUIGANTRYNR> will be
updated
1
1120048 GUIReqRevPos Message from GUI: Request revolver
position and <GUIGANTRYNR> will
be updated
1
1120049 GUIActuateDP Message from GUI: Actuate dp-axis
and <GUIGANTRYNR> will be
updated
1
1120050 GUIComAirPickUp Message from GUI: Compressed air
at pick-up position and
<GUIGANTRYNR> will be updated
1
1120051 GUIVacPickUp Message from GUI: Vacuum at pick-
up position and <GUIGANTRYNR>
will be updated
1
1120052 GUIComAirPlace Message from GUI: Compressed air
at placement position and
<GUIGANTRYNR> will be updated
1
1120053 GUIVacPlace Message from GUI: Vacuum at
placement position and
<GUIGANTRYNR> will be updated
1
1120054 GUIMeaVacPickUp Message from GUI: Measure vacuum 1