00192402-01.pdf - 第180页

GEM for SIPLACE V7.01 Page 180 of 251 ©Siemens AG, all rights r eserved 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ / $ &RPSRQHQW1DPH! 83DFNDJH)RUP1XPE HU! 85HVXOW! 0:Ok ; 1:Error ,0D[/HDG &apos…

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 179 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
An empty list indicates an error.
1512004 SV L NOZZLERETURN
Last nozzle returned to the nozzle-changer by the IC-
head. Only valid for SIPLACE 80F. On a SIPLACE
80S this variable will contain an empty list.
/
812==/(B7<3(!
,5($/B12==/(B/(1*7+!>PP@
!
The nozzle length is measured during the reference
run. It depends on the HEIGHTIC value. So
REAL_NOZZLE_LENGTH is not a absolute but a
relative value.
It is calculated by subtracting the measured distance
between the nozzle and the upper edge of the
conveyor belt from the HEIGHTIC value.
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
1512010 SV L VACUUMDATAIC
Vacuum measurements IC-Head. Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
,RSHQBQR]]OH!
,FORVHGBQR]]OH!
,FXELFBQR]]OH!
,QRWBFXELFBQR]]OH!
,WROBGLUW\BQR]]OH!
,WROBOHDN\BQR]]OH!
!
tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
1512013 SV L COPLANARITYDATAIC
Result of last coplanarity measurement. Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
GEM for SIPLACE V7.01
Page 180 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
/
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
85HVXOW!0:Ok; 1:Error
,0D[/HDG'HY!>PP@
!
The coplanarity module measures the height of all
leads and calculates then a hypothetical plane through
the three highest leads. 0D[/HDG'HY is the greatest
deviation between one lead and this plane.
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
1512014 SV L PLACEINFOIC
Placement information for IC-head 2 Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
8;SRVLWLRQ!>PP@
8<SRVLWLRQ!>PP@
)$QJOH!>GHJUHHV@
8)RUFH,QGH[!
$5HIHUHQFH'HVLJQDWRU!
$&RPSRQHQW1DPH!
83DFNDJH)RUP1XPEHU!
83ODFHPHQW5HVXOW!
,3ODFHPHQW9DFXXP!
,9DFXXP!
8'DWD9DOLG!
,;GHYLDWLRQ!>PP@
,<GHYLDWLRQ!>PP@
)$QJOH!>GHJUHHV@
84XDOLW\!>@
8/HQJWK!>PP@
8:LGWK!>PP@
/
,3LWFKBSHUBOHDGBJURXS!

,3LWFKBSHUBOHDGBJURXS!
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 181 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
!
)0D[/HDG'HY!>PP@
)0D[%DOO'HY!>PP@
)2UWKR'HY!>GHJ@
8/HDG&RXQW!
!
The fields following the data item DataVaild
represent the result of optical centering. All fields are
not necessarily valid for all package forms. Verify the
validity of a field using the data valid byte and refer to
the corresponding flag for the appropriate field.
[;GHY<GHYDQGDQJOH
[OHQJWKDQGZLGWK
[OHDGFRXQW
[SLWFK
[RUWKRJRQDOGHYLDWLRQ
[PD[OHDGGHYLDWLRQ
[PD[EDOOGHYLDWLRQ
For a detailed description of the data item see 4.2
Data Item Dictionary.
An empty list indicates an error.
1512015 SV L PICKUPINFOIC
Pick-up information for IC-head . Only valid for
SIPLACE 80F. On a SIPLACE 80S this variable will
contain an empty list.
/
$&RPSRQHQW1DPH!
,7UDFN1XPEHU!
8)HHGHU7\SH!
,/HYHO!
,'LYLVLRQ!
80DFKLQH6LGH!
83LFN8S5HVXOW!
,3LFN8S9DFXXP!
,9DFXXP!
!
If the component was picked up from a feeder /HYHO
will contain -1. In the case that the component was
picked up from a tray in the waffle pack changer
7UDFN1XPEHU is set to -1. If both values are not equal