00192402-01.pdf - 第110页

GEM for SIPLACE V7.01 Page 110 of 251 ©Siemens AG, all rights r eserved  6)(YHQW5H SRUW S6F11 W * H<-E <L [3] <U4 DATAID> * DATAID <U4 CEID> * Collection Event ID <L <L [2] <U4 RPT…

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 109 of 251
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFKGR
QRWVXSSRUW*(0
If the Equipment Constant "ConfigEvents" is set to "0", the Equipment sends S6F9 instead
of the normal S6F11 Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "False"
(normal report format desired). The Equipment sends one or more Event Reports which
the Host has previously linked to that CEID (see S2F35). Each report contains specific
Variables which the Host has previously defined for that Report (see S2F33).
PCFD is always zero.
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F9 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F9 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F9 has the following
special format:
S6F9 [W] * H<-E
<L [4]
<B [1] 00> * PFCD
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
Equipment Constant "WBitS6" controls whether the Equipment sends S6F9 with W-Bit "1"
(Reply Expected) or "0" (No Reply Expected).
 6)(YHQW5HSRUW
S6F10 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.
GEM for SIPLACE V7.01
Page 110 of 251 ©Siemens AG, all rights reserved
 6)(YHQW5HSRUW
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
This message is the "normal" message that the Equipment uses to report events. In
order for this message to be used, the Equipment Constant "ConfigEvents" must be set to
"1".
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "False"
(normal report format desired). The Equipment sends one or more Event Reports which
the Host has previously linked to that CEID (see S2F35). Each report contains specific
Variables which the Host has previously defined for that Report (see S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F11 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F11 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following
special format:
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
 6)(YHQW5HSRUW
S6F12 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 111 of 251
 6)$QQRWDWHG(YHQW5HSRUW6HQG
S6F13 W * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<L [2]
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .
1RWH7KLVPHVVDJHLVSURYLGHGRQO\IRUFRPSDWLELOLW\ZLWKROGHU+RVWFRPSXWHUVZKLFK
VXSSRUWROGHUYHUVLRQVRI*(0
A Collection Event has occurred at the Equipment. The Host has enabled event reporting
for this CEID (see S2F37). The Host has set the Equipment Constant RpType to "True"
(Annotated report format desired). The Equipment Constant ConfigEvents has been set
to 1. The Equipment sends one or more Event Reports which the Host has previously
linked to that CEID (see S2F35). Each report contains specific Variables which the Host
has previously defined for that Report (see S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F11 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F11 will match DATAID in S6F5.