GEM for SIPLACE V7.01 Page 186 of 251 ©Siemens AG, all rights r eserved 9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ following station is s et. Bit 4: If bit is set, the m otor of the width adjustm ent is in f ast…

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 185 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
Bit 6: If bit is set, the stopper will extend.
Bit 7: Operates the ceramic substrate centering.
A value of -1 indicates an error
2012008 SV U1 OUTPUTPORTBYTE2
Bit 0: If bit is set, the right main malfunction
indicator illuminates.
Bit 1: If bit is set, the green light of the main
malfunction indicator illuminates.
Bit 2: If bit is set, the left main malfunction
indicator illuminates.
Bit 3: If bit is set, the barcode of the parallel
conveyer will be triggered.
Bit 4: If bit is set, the monitor of the ICOS will be
activated.
Bit 4/5: If bit 4 and 5 are set, the monitor of M44 will
be activated.
Bit 6: If bit is set, the barcode will be triggered.
Bit 7: If bit is set, the operation voltage will be
switched on.
A value of -1 indicates an error
2012009 SV U1 OUTPUTPORTBYTE3
Bit 0: Free for a second conveyor motor.
Bit 1: Free for a second conveyor motor.
Bit 2: If bit is set, the motor of the center
conveyor is in slow mode.
Bit 3: If bit is set, the motor of the center
conveyor is in fast mode.
Bit 4: If bit is set, the motor of the output conveyor
is in slow mode 1.
Bit 5: If bit is set, the motor of the output conveyor
is in fast mode.
Bit 6: If bit is set, the motor of the output conveyor
is in slow mode 2.
Bit 7: If bit is set, the motor of the input conveyor
is in fast mode.
A value of -1 indicates an error
2012010 SV U1 OUTPUTPORTBYTE4
Bit 0: The Interface signal "Request" from the
preceding station is set.
Bit 1: The Interface signal "Sent" from the
preceding station is set.
Bit 2: The Interface signal "Permission" to the
following station is set.
Bit 3: The Interface signal "Received" to the

GEM for SIPLACE V7.01
Page 186 of 251 ©Siemens AG, all rights reserved
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
following station is set.
Bit 4: If bit is set, the motor of the width
adjustment is in fast mode.
Bit 5: If bit is set, the width is being adjusted
smaller.
Bit 6: If bit is set, the width is being adjusted
larger.
Bit 7: If bit is set the component counter will count
one component.
A value of -1 indicates an error
2012011 SV U1 OUTPUTPORTBYTE5
Bit 0: If bit is set, lifting table of the second
transport track is moving up.
Bit 1: If bit is set, lifting table of the second
transport track is moving down.
Bit 2: If bit is set, the motor of the center
conveyor of the second transport track is in
slow mode.
Bit 3: If bit is set, the motor of the center
conveyor of the second transport track is in
fast mode.
Bit 4: If bit is set, the motor of the output conveyor
of the second transport track is in slow
mode 1.
Bit 5: If bit is set, the motor of the output conveyor
of the second transport track is in fast
mode 1.
Bit 6: If bit is set, the motor of the output conveyor
of the second transport track is in slow
mode 2.
Bit 7: If bit is set, the motor of the input conveyor
of the second transport track is in fast
mode 2.
A value of -1 indicates an error
2012012 SV U1 OUTPUTPORTBYTE6
Bit 0: The Interface signal "Request" to the
preceding station of the second transport
track is set.
Bit 1: The Interface signal "Sent" to the preceding
station of the second transport track is set.
Bit 2: The Interface signal "Permission" to the
following station of the second transport
track is set.
Bit 3: The Interface signal "Received" to the
following station of the second transport
track is set.
Bit 4: If bit is set, the motor of the width
adjustment of the second transport track is

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 187 of 251
9,' &ODVV )RUPDW 1DPHDQG'HVFULSWLRQ
in fast mode.
Bit 5: If bit is set, the width of the second
transport track is being adjusted smaller.
Bit 6: If bit is set, the width of the second
transport track is being adjusted larger.
Bit 7: Operates the ceramic substrate centering
of the second transport track.
A value of -1 indicates an error
2012013 SV U2 ERRORTYPE
Type of the most recent error
2 Transport
3 Track error
4 Machine error
5 Miscellaneous
A value of 0 indicates an error.
2012014 SV U2 GANRTYONERROR
Gantry associated with the most recent error
A value of 0 indicates an error.
2012015 SV U2 SEGMENTONERROR
Segment number associated with the most recent
error
A value of 0 indicates an error.
2012016 SV U2 TRACKONERROR
Track number associated with the most recent error
event
In the case that the component was picked up from a
tray in the waffle pack changer TRACKONERROR is
set to 0
2012017 SV U2 ERRORINFO1
A value of 0 indicates an error.
2012018 SV U2 ERRORINFO2
A value of 0 indicates an error.
2012019 SV L PICKUPERRORS
Pick-Up Errors. This data item will be reset when a
new Process Program is downloaded to a SIPLACE