00192402-01.pdf - 第74页

GEM for SIPLACE V7.01 Page 74 of 251 ©Siem ens AG, all rights reserved  6)6WDWXV9DULDEOH1 DPHOLVW5HSO\ S1F12 * H<-E <L <L [3] <U4 VID> * Variable ID <A SVNAME> * Status Variable Nam e …

100%1 / 251
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 73 of 251
For compatibility with older Host implementations, the Equipment allows the following
alternative form for this message using an array format:
S1F4 W * H->E
<U4 VID...>.
 6)6HOHFWHG6WDWXV'DWD
S1F4 W * H<-E
<L
<V> * Status Variable Value
...
> .
The Equipment returns the Variable Values in the order requested by S1F3. If any VID
specified in S1F3 is invalid, the corresponding V in S1F4 has the following error format:
<L> * V for Invalid VID
 6)6WDWXV9DULDEOH1DPHOLVW5HTXHVW
S1F11 W * H->E
<L
<U4 VID> * Status Variable ID
...
>.
The Host format descriptions for the specified Variables. Several VIDs can be specified if
desired.
Normally, only VIDs of class SV (i.e. Status Variables) are used in this message.
However, any VID of class DV, EC, or SV can be used.
If S1F11 contains a zero-length list, then the Equipment will report all variables of class
SV, in order by VID.
S1F11 W * H->E
<L> .
GEM for SIPLACE V7.01
Page 74 of 251 ©Siemens AG, all rights reserved
 6)6WDWXV9DULDEOH1DPHOLVW5HSO\
S1F12 * H<-E
<L
<L [3]
<U4 VID> * Variable ID
<A SVNAME> * Status Variable Name
<A UNITS> * Units of Measure
...
> .
The Equipment returns the Variable descriptions in order requested in S1F11. If any VID
specified in S1F11 is invalid, the corresponding List in S1F12 has the following error
format:
<L> * Instead of L [3]
 6)&RQQHFW5HTXHVW
The Equipment sends this message using the following format.
S1F13 W * H<-E
<L
<A MDLN>
<A SOFTREV>
> .
The Host sends this message using the following format.
S1F13 W * H->E
<L> .
Either end of the link may send S1F13 as the first message to establish connection of the
link.
Under the SIPLACE's initialization logic, the Equipment will always attempt to establish the
link. If no Host acceptance reply is received, the Equipment sends this message
periodically.
GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 75 of 251
 6)&RQQHFW5HTXHVW$FNQRZOHGJH
The Equipment sends this message using the following format:
S1F14 * H<-E
<L
<B [1] 00> * COMMACK
<L
<A MDLN>
<A SOFTREV>
>
> .
The Host sends this message using the following format:
S1F14 * H->E
<L
<B [1] 00> * COMMACK
<L>
> .
The Equipment always sends the value 0x00 for COMMACK.
In messages received from the Host, COMMACK value 0x00 indicates acceptance of the
connect request. Any other value indicates refusal.
 6)5HTXHVW2II/LQH
S1F15 W . * H -> E
Host requests the Equipment to go Off-Line.
 6)2II/LQH$FNQRZOHGJH
S1F16 * H <- E
<B [1] 0x00> . * OFLACK
Equipment Control State transits to Host Off-Line and sends this message in response to
S1F15 primary. OFLACK is always zero.
 6)5HTXHVW2Q/LQH
S1F17 W . * H -> E
Host requests the Equipment to go On-Line.
 6)2Q/LQH$FNQRZOHGJH
S1F18 * H <- E
<B [1] ONLACK> .