GEM for SIPLACE V7.01 ©Siemens AG, all rights r eserved page 59 of 251 SEGMENTINFO IC: Number of com ponents which were placed succ essf ully by the actual nozz le. Form at:I2 used in : GANTRYINFO1, GANT RYINFO2, GANTRYI…

GEM for SIPLACE V7.01
Page 58 of 251 ©Siemens AG, all rights reserved
&((' - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
&(,' - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
&/2&. - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
FORVHGBQR]]OH Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAREV1, VACUUMDATAREV2, VACUUMDATAIC
&0'$ - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
&RPS&RXQW Number of components per tray in the waffle pack changer
Format: I2
used in : INVENTARYWPC
&RPS/HIW3ODFH Number of components which are left to be placed on the actual
PCB
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC
&RPS3LFNHG8S Number of components which were picked up successfully per
Gantry or Segment since the current PCB reached the center
conveyor.
SEGMENTINFOIC:
Number of components which were picked up successfully by the
actual nozzle.
Format: I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC, SEGMENTINFOREV1,
SEGMENTINFOREV2, SEGMENTINFOIC
&RPS3ODFHG Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.

GEM for SIPLACE V7.01
©Siemens AG, all rights reserved page 59 of 251
SEGMENTINFOIC:
Number of components which were placed successfully by the actual
nozzle.
Format:I2
used in : GANTRYINFO1, GANTRYINFO2, GANTRYINFOIC, SEGMENTINFOREV1,
SEGMENTINFOREV2, SEGMENTINFOIC
&RPSRQHQW1DPH - Name of a component
Format: A
used in: PLACEINFOREV1, PLACEINFOREV2, PICKUPINFOREV1
PICKUPINFOREV2, VISIONDATAIC, COPLANARITYDATAIC,
INVENTARYWPC, PARTNRPLACEIC,
&RSODQDULW\(UURUV -Number of coplanarity errors since last download of a process
program
Format: U2
used in: PICKUPERRORS
&3$&. - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
&31$0( - Command Parameter Name
Format: A
used in: S2F41, S2F42
&39$/ - Command Parameter Value
Format:
used in: S2F41
FXELFBQR]]OH Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATEREV1, VACUUMDATAREV2, VACUUMDATAIC
'$7$,' - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
'$7$/(1*7+ - Data Length
Format: U4

GEM for SIPLACE V7.01
Page 60 of 251 ©Siemens AG, all rights reserved
used in: S2F39, S6F5
'DWD9DOLG
The fields following the data item „DataValid“ represent the result of optical centering. All
fields are not necessarily valid for all package forms. Verify the validity of a field using the
„data valid“ byte and refer to the corresponding flag for the appropriate field.
0x0001 X-dev, Y-dev. and angle
0x0002 length and width
0x0004 lead count
0x0008 pitch
0x0010 orthogonal deviation
0x0020 max. lead deviation
0x0040 max. ball deviation
'LYLVLRQ - Division at a feeder or a level in the waffle pack changer
Format: I2
used in: PICKUPINFO1, PICKUPINFO2, INVENTARYWPC, DIVISIONIC
'5$&. - Define Report Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
'63(5 Data Sample Period
Format: A
used in: S2F23
($& - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
(&'() - Equipment Constant Default Value
Format:
used in: S2F30
(&0$; - Equipment Constant MaximumValue