Assembly instructions Nozzle changer SIPLACE X-Series / D3 11/2011 Edition 38 2.2 Safety instructions W ARNING The safety instructio ns from the “Operational sa fety” chapter of the user ma nual and servicing in- structi…

100%1 / 70
Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
37
2 Assembly instructions Nozzle
changer SIPLACE X-Series / D3
2.1 Parts required
2.1.1 Tools and consumables required
Set of hexagon socket spanners 2
Set of screwdrivers 2
Set of TORX drivers 2
Hammer 2
2.1.2 Possible nozzle changer configurations
2
2
2
The following are also recommended for the C&P 20 placement head: 2
C+P 12 head
HF nozzle changer, 12-seg. C+P head 00119661-xx
HF nozzle changer 2, 12-seg. C+P head 00119663-xx
C+P 6 head
HF nozzle changer, 6-seg. C+P head 00119662-xx
HF nozzle changer 2, 6-seg. C+P head 00119664-xx
C+P 20 head (only X-Series)
X series/C+P20 nozzle changer 00119715-xx
Add. X series/C+P20 nozzle changer 00119716-xx
Sensor for component reject bin 00116848-xx
Retrofit inst. reject bin for HF /X series 00194550-xx
Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
38
2.2 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at cer-
tain modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent it
being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.2.1 Definitions
2
Please note 2
2
Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
39
2.3 Connecting the nozzle changers to the CAN Nodes
The main task of the CAN node is to control the tape cutter. The cables are run as a default in the
component feed device and connected to the CAN node option. The connectors can therefore be
found on the back of the component feed device, above the empty tape duct. 2
2
2
Although some component feed devices already have the cables for the CAN node module ready,
the old version of the cutter control is still used. In this case, you either need to convert to the CAN
node module or use the 1 wire hub. 2
Mixed configurations in the same machine are not possible.
Old cutter control board: [03006411-xx]
New cutter control board for CAN node module [03052927-xx]
From machine number B752 the component feed device has been converted fully to the
CAN node option.
For conversion to the CAN nodes option, please contact your SIPLACE Service team.
2.4 Installing the one-wire hub (all nozzle changers)
The 1 wire hub is used to control the following options up until SW605: 2
Verify sensors for reject bin
Nozzle changers for C&P20, C&P6 and C&P12
2
2
If one of these two options is already fitted at the relevant location, an additional 1 wire hub is not
required. 2
2
: Switch the placement system off at the main switch.
2
: Pull the patch cable
(item no. 03041628-xx for location 1 + 3 / item no. 03041627-xx for location 2 + 4)
out of the opening in the machine frame (see photograph below).
2
2
Do not run the cable together with the wiring harness in order to avoid electrical interference. 2