00194482-02_AI_NozzleChanger_X_605_DE+EN.pdf - 第43页
Assembly instructions Nozzle changer SIPLACE X-Series / D3 11/2011 Edition 43 2.5 Setting the height 2.5.1 Setting the height of the nozzle changer contact surface : Push the placement head inwards for the measure ment o…

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
42
2
2
Connecting cable
2 screws
(DIN 6912-M4 x 8-8.8, item no.: 00095106-xx)

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
43
2.5 Setting the height
2.5.1 Setting the height of the nozzle changer contact surface
: Push the placement head inwards for the measurement on the outer side.
: Move the gantry so that the placement head is roughly at the subsequent nozzle changer po-
sition (photographs C&P 6/12).
2
Make sure that, in the subsequent measurement, the tip of the caliper gauge does not touch the
magnetic rail for the internal measurement since it could damage the rail. 2
2
: Place the caliper gauge on the top edge of the lower X-axis linear guide and measure up to the
nozzle changer contact surface.
2
Hold the caliper gauge vertically. 2
2
2
Tip of the caliper gauge
Magnetic surface
Support the lower end of the
caliper gauge here
Measure up to the nozzle
changer contact surface.

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
44
: Push the placement head outwards for the inner measurement.
: Measure the distance on the inside.
2
2
: The ideal measured value is 150.0 +/- 0.2 mm.
If the distance is correct, then start installation of the nozzle changer in the placement machine.
If the distance is greater, insert spacers beneath the contact surfaces.
2
2
2
2
2
2
2
2
2
Distance to be measured