00194482-02_AI_NozzleChanger_X_605_DE+EN.pdf - 第52页
Assembly instructions Nozzle changer SIPLACE X-Series / D3 11/2011 Edition 52 : Connect the second nozzle ch anger to the one-wire hub . 2 2 : Connect the compr essed air hose and reco nnect the two nozzle ch angers to t…

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
51
Fitting the second row of C&P20 nozzle changers 2
: Fit the mounts for the second row of nozzle changers and check the height as described in sec-
tion 1.3.1 Setting the height of the nozzle changer contact surface.
: Tap the dowel pins (DIN 6325 - 5m6 x 14-St, item no.: 00323142-xx) into the relevant holes in
the mount and screw the mount in place as shown (screws DIN 7991-M5 x 12-8.8, item no.:
00306624-xx).
2
: Tap the pins into the relevant holes in the nozzle ejector mount and screw the mount on as
shown.
2
Pins
DIN 6325 - 5m5 x 16-St, item no.: 00619866-xx
Screws
DIN912-M5 x 16-8.8, item no.: 00845044-xx

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
52
: Connect the second nozzle changer to the one-wire hub.
2
2
: Connect the compressed air hose and reconnect the two nozzle changers to the compressed
air supply using a Y-piece.
2
2
Nozzle changer
connecting cable
Slot for the
reject bin sensor

Assembly instructions Nozzle changer SIPLACE X-Series / D3
11/2011 Edition
53
2.7 Nozzle changer, C&P 6/12 placement head
: Switch the placement system off at the main switch.
: Tap the pins into the appropriate holes in the nozzle ejector mount.
2
2
2
2
2
2
2
2
2
2
2
2
Pins
DIN 6325 - 5m5 x 16-St, item no.: 00619866-xx
Screws