00194547-09_InstallationManual_60103SP4_EN_DE.pdf - 第38页

Installation Manual, Station Software Version 601.03 SP4 Edition 05/2007 4.4 Machine files There are 2 databases in Version 601 of the software, MA-Daten.mdb and MA-Achsen.mdb . Machine-related configuration, measurement…

100%1 / 179
Installation Manual, Station Software Version 601.03 SP4 Edition 05/2007
Finalizing uninstallation
Fig. 4-17: Finalizing uninstallation
Click the Finish button.
The SIPLACE software and SIPLACE Vision have now been uninstalled correctly.
37 of 89
Installation Manual, Station Software Version 601.03 SP4 Edition 05/2007
4.4 Machine files
There are 2 databases in Version 601 of the software, MA-Daten.mdb and MA-Achsen.mdb.
Machine-related configuration, measurement and parameter data is stored in *.XML and *.MA files.
The MA-Daten.mdb database contains all standard data except the standard data for the axes. This
data is stored in the MA-Achsen.mdb database.
Note:
All machine data and the machine database (MA-Daten.mdb) must be of revision
level 62 (version 62.601.03). Current machine data must
not be replaced by revision levels of an
earlier version, either completely or partially, e.g. revision level 50 (version 50.505.01).
38 of 89
Installation Manual, Station Software Version 601.03 SP4 Edition 05/2007
4.5 Installing the machine controller on a CPU076 (SIPLACE X-series)
4.5.1 BIOS setup
The CPU buffers the current CMOS settings in a flash EPROM. If the CMOS settings are lost, they
will be restored from the flash settings on the next power-up.
Note:
For a detailed description of the BIOS, see the technical description CPCI-/SMP16-CPU076.
Settings marked in blue, bold and italics have been changed from the default BIOS settings.
4.5.1.1 IDE Primary/Secondary Master/Slave
Auto
The device parameters are automatically determined when the system is
started.
Manual The device parameters can be entered by hand (only in Access Mode CHS).
None
No IDE device has been connected or a connected device is to be ignored.
Auto is set by default.
4.5.1.2 Access Mode
Auto
The device parameters are automatically determined when the system is
started.
LBA Hard disks > 528MB which support Logic Block Addressing mode (LBA).
CHS Hard disks < 528MB
Large Hard disks > 528MB which do not support Logic Block Addressing mode
(LBA).
Auto is set by default.
If Manual and CHS are selected for the device, the disk parameters can be entered.
Cylinder
Number of cylinders
Head Number of read/write heads
Precomp Write precompensation
Landing Zone Landing zone
Sector Number of sectors / cylinders
39 of 89