00198596-02_JC_3M_C&P20P2M3_EN.pdf - 第10页
www.asm-smt.com

1 3-monthly C&P20 P2/M3 Mount the C&P20 P2/M3 head 1 min 1 / 1
Refer to safety instructions in user manual before commencing Maintenance!
NOTICE! ESD guidelines are to be followed! Tool:
T7, T8, T9, T21, T95
Wear Part: Consumables:
www.asm-smt.com
1 Use the marked screw holes. 2 Mount the head at the headstand with a
torque of 2,70 Nm.
3 Remove the component sensor protection.
4 ATTENTION: Work carefully close to the
component sensor as the glass of the
prism can easily be damaged!

www.asm-smt.com

2 3-monthly C&P20 P2/M3 Remove the holding circuit / orifice plate 2 min 1 / 2
Refer to safety instructions in user manual before commencing Maintenance!
NOTICE! ESD guidelines are to be followed! Tool:
T21, T32, T44, T78
Wear Part:
W10, W32
Consumables:
www.asm-smt.com
1 Put the head stand in the upright position
and turn the head upside down.
2 To remove the holding circuit(1) proceed
with next step. For the orifice plate(2) pro-
ceed with step 6.
3 Dismantle the silencer.
4 Remove the three protruding screws from
the holding circuit.
5 Remove the holding circuit with the seal to
clean it and proceed with next task. See
appendix "Maintain the holding circuit".
6 Dismantle the cover.