00198596-02_JC_3M_C&P20P2M3_EN.pdf - 第14页

www.asm-smt.com

100%1 / 62
3 3-monthly C&P20 P2/M3 Clean the return unit 1 min 1 / 1
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T21
Wear Part: Consumables:
C3, C5, C22
www.asm-smt.com
1 Turn the head right side up and put the
headstand flat on the table.
2 Pull out the return cylinder. 3 Clean the upper contact area.
4 Clean the lower contact area. 5 Clean the shaft of the return unit.
www.asm-smt.com
4 3-monthly C&P20 P2/M3 Clean the Z-axis 3 min 1 / 2
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T3, T7, T21, T41, T96, T97, T98
Wear Part: Consumables:
www.asm-smt.com
1 Proceed with the headstand flat on the
table.
2 Remove the long screw at the side. Be
careful that no screws fall into the head!
3 Remove the short screw at the side of the
Z-axis cover.
4 Remove the 2 screws close to the star and
dismantle the cover plate.
5 Clamp the black rubber hose between Z-
axis and driver of the return unit.
6 Remove all components from the magnets
holding the Z-axis flex print.