00198596-02_JC_3M_C&P20P2M3_EN.pdf - 第43页

11 3-monthly C&P20 P2/M3 Mount the holding circuit / orifice plate 8 min 3 / 4 Refer to safety instructions in user manual before commencing Maintenance NOTICE! ESD guidelines are to be followed Tool: T21, T44, T78 W…

100%1 / 62
11 3-monthly C&P20 P2/M3 Mount the holding circuit / orifice plate 8 min 2 / 4
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T21, T44, T78
Wear Part:
W10, W18
Consumables:
C3, C5, C11, C22
www.asm-smt.com
7 If not OK replace it with a new one. 8 Place the seal properly on a maintained
holding circuit.
9 Insert the maintained holding circuit with a
seal attached into the star carrier. Take
care of the correct fitting pin position.
10 Fasten the three protruding fixing screws
with a torque of 0.25 Nm.
11 Check the silencer for dirt or damages. 12 If OK proceed with step 14.
11 3-monthly C&P20 P2/M3 Mount the holding circuit / orifice plate 8 min 3 / 4
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T21, T44, T78
Wear Part:
W10, W18
Consumables:
C3, C5, C11, C22
www.asm-smt.com
13 If not OK replace it with a new one. 14 Return the silencer. Ensure the proper
seating by pressing it onto the star carrier.
15 Fasten the screw at the silencer hand-
tight.
16 Mount the orifice plate and the cover. 17 Check the seal for dirt and damage. 18 If Ok proceed with step 20.
11 3-monthly C&P20 P2/M3 Mount the holding circuit / orifice plate 8 min 4 / 4
Refer to safety instructions in user manual before commencing Maintenance
NOTICE! ESD guidelines are to be followed Tool:
T21, T44, T78
Wear Part:
W10, W18
Consumables:
C3, C5, C11, C22
www.asm-smt.com
19 If not OK replace it with a new one. 20 Place the seal properly on a maintained
orifice plate.
21 Insert the maintained orifice plate into the
star carrier. Take care of the correct fitting
pin position.
22 Fasten the three protruding fixing screws
with a torque of 1,3 Nm.
23 Ensure the O-ring sits in the correct posi-
tion and is lubricated slightly over the
whole length.
24 Return the cover and fasten it hand-tight.