SIPLACE S-23 HM.pdf - 第233页

User Manual SIPLAC E S-23 HM 6 Vision functions Software Version SR.406.xx 02/00 US Edition 6. 5 Teach Fiducial 233 6.5.6 T est Fiducial Menu In the T es t fiducial menu the fol lowing options are avai lable: 6 – Centeri…

100%1 / 454
6 Vision functions User Manual SIPLACE S-23 HM
6.5 Teach Fiducial Software Version SR.406.xx 02/00 US Edition
232
Setting the contrast sensitivity to suppress defective structures and intensify the contrast at
the same time 6
Å Select the following settings to suppress defective structures and at the same time to intensify
the contrast for low-contrast fiducials:
6
Fig. 6.5 - 22 Setting the contrast sensitivity to suppress defective structures and
to intensify the contrast at the same time
6
6
User Manual SIPLACE S-23 HM 6 Vision functions
Software Version SR.406.xx 02/00 US Edition 6.5 Teach Fiducial
233
6.5.6 Test Fiducial Menu
In the Test fiducial menu the following options are available: 6
Centering the fiducial (Center)
Testing the fiducial (Test)
Positioning the teaching gantry (x/y movement) (move X/Y axes)
Transporting the board onto the output conveyor (PCB to output conveyor)
Transporting the board onto the center conveyor (PCB to center conveyor)
6
Fig. 6.5 - 23 Test fiducial menu, options
NOTE 6
Buttons are active when the text on the button is black (rather than gray). This means that you can
launch the associated function by clicking on the button with the mouse.
The Center and Test options will only be available if you have already loaded a fiducial and a
model already exists for this fiducial. 6
6 Vision functions User Manual SIPLACE S-23 HM
6.5 Teach Fiducial Software Version SR.406.xx 02/00 US Edition
234
If you have selected a fiducial the fiducial number and the fiducial name will appear in the display
field. 6
6.5.6.1
Center
Option
If you click on the Center button the Test fiducial menu will close and the video image is shown
on the screen. The picture shows the 2D fiducial structure and the rows and columns profiles of
the 1D structure used for determining precisely the center of the fiducial. Header and footer will
be shown as well. 6
6
Fig. 6.5 - 24 Test fiducial menu, Center video image
The Center function determines via software the center of the fiducial. The parameters for the
function, the edges of the fiducial structure, are selected via a dialog. The system draws edge line
markings as suggestions at possible edge positions. 6
Å With the arrow keys shift the current edge line marking designated in the header.
Å With Return you can accept the position of the suggested edge line marking or the one whose
position you changed. The system will then show you the next edge line marking. The se-
quence in which testing takes place is ’Fiducial edge left’, ’Fiducial edge right’, ’Fiducial edge
top’, and lastly, ’Fiducial edge bottom’. This notation appears in the header.
Edge ok
Fiducial No. = 8 Edge = left
Ret :
Center fiducial
: up
: dn
: right
: left
Fiducial
Result: Centering crosshair
Edge line markings to be shifted
via cursor keys
Row profile of fiducial
Column profile
of fiducial