SIPLACE S-23 HM.pdf - 第51页

User Manual SIPLAC E S-23 HM 1 Introduction, technical dat a Software Vers ion SR.406.xx 02/00 US Edition 1. 15 Overv iew of the modules - P CB conveyor 51 1 PCB tran sport he ight 830 mm ± 15 mm (stan dard) 900 m m ± 15…

100%1 / 454
1 Introduction, technical data User Manual SIPLACE S-23 HM
1.15 Overview of the modules - PCB conveyor Software Version SR.406.xx 02/00 US Edition
50
The conveyor belts are driven by DC motors. The lifting table near the center conveyor clamps the
PCBs in position. The width of the PCB conveyor can be adjusted either 1
via the menu or
using the line computer.
1
1.15.2 Technical data – single conveyor
1
1
1.15.3 Technical data – dual conveyor
1
PCB format 50mm x 50mm to 460mm x 460mm
2" x 2" to 18" x 18"
Optionally: up to 508mm x 460mm
up to 20" x 18 "
PCB thickness 0.5mm to 4.5mm
Max. PCB warpage On top: 4.5mm - PCB thickness
On bottom: 0.5mm + PCB thickness
Clearance on PCB underside 25mm (standard), 40mm (option)
PCB transport height 830mm ± 15mm (standard)
900mm ± 15mm (option)
930mm ± 15mm (option)
950mm ± 15mm (SMEMA: optional)
Fixed conveyor edge Right (standard), left (optional)
Type of interface Siemens (standard), (SMEMA: optional)
Component-free handling edge 3mm
PCB changeover time 2.5 s
PCB format 50mm x 50mm to 460mm x 216mm
2" x 2" to 18" x 8.5"
Optionally: up to 508mm x 216mm
up to 20" x 8.5 "
PCB thickness 0.5mm to 4.5mm
Max. PCB warpage On top: 4.5mm - PCB thickness
On bottom: 0.5mm + PCB thickness
Clearance on PCB underside 25mm (standard), 40mm (option)
User Manual SIPLACE S-23 HM 1 Introduction, technical data
Software Version SR.406.xx 02/00 US Edition 1.15 Overview of the modules - PCB conveyor
51
1
PCB transport height 830mm ± 15mm (standard)
900mm ± 15mm (option)
930mm ± 15mm (option)
950mm ± 15mm (SMEMA: optional)
Fixed conveyor edge Right (standard), left (optional)
Type of interface Siemens (standard), (SMEMA: optional)
Component-free handling edge 3mm
PCB changeover time 2.5 s
Components on each conveyor Synchronous: same or different, asynchronous: same
PCB width on each conveyor Synchronous: different, asynchronous: same
Ink spot recognition Synchronous: not possible, asynchronous: possible
Automatic width adjustment Synchronous: not possible, asynchronous: possible
1 Introduction, technical data User Manual SIPLACE S-23 HM
1.15 Overview of the modules - PCB conveyor Software Version SR.406.xx 02/00 US Edition
52