D3操作手册.pdf - 第36页
36 Technical Data Siemens Signal Interface Connector Assignment Signal interface (20-pole ribbon cable con nector) Upstre am station X1 Dow nstream station X2 Pin 1 R eserved Pin 1 Rese r ved Pin 2 GND 2 4 VDC Pin 2 Rese…

35
Sample Configuration
Services
As a service, SIEMENS A&D
EA can fully integrate the
SIPLACE D3 placement
machine into your produc-
tion line. With our extensive
expertise and by using the
right tools and equipment,
we can ensure that the instal-
lation process runs smoothly
and efficiently. However, this
will require you to clarify the
infrastructure aspects in ad-
vance and make any neces-
sary changes at your
production facility.
Safety instructions
Read the operating instruc-
tions before starting to set up
and commission the place-
ment machine. The applica-
ble accident prevention
regulations concerning the
transportation of heavy
goods must be followed.
Nozzle changer C&P12
Component
changeover table
with 15 locations
Nozzle Changer (TwinHead)
5-part conveyor belt
with automatic width adjustment
from 50 mm to 508 mm (2“ to 20“)
Nozzle Changer (TwinHead)
Component
changeover table
with 15 locations
Nozzle changer C&P12
Component changeover table
with 15 locations
C&P12
C&P12
TH

36
Technical Data
Siemens Signal Interface
Connector Assignment
Signal interface (20-pole ribbon cable connector)
Upstream station X1 Downstream station X2
Pin 1 Reserved Pin 1 Reserved
Pin 2 GND 24 VDC Pin 2 Reserved
Pin 3 + 24 VDC Pin 3 Reserved
Pin 4 Reserved Pin 4 Reserved
Pin 5 Reserved Pin 5 GND 24 VDC
Pin 6 Reserved Pin 6 + 24 VDC
Pin 7 Reserved Pin 7 Reserved
Pin 8 Reserved Pin 8 Reserved
Pin 9 Reserved Pin 9 Reserved
Pin 10 Reserved Pin 10 Reserved
Pin 11 Interfering signal loop Pin 11 Interfering signal loop
Pin 12 Interfering signal loop Pin 12 Interfering signal loop
Pin 13 GND 24 VDC Pin 13 GND 24 VDC for permission / arrived
(galvanic isolation)
Pin 14 Arrived Pin 14 Arrived
Pin 15 Permission Pin 15 Permission
Pin 16 Reserved Pin 16 Reserved
Pin 17 Reserved Pin 17 Reserved
Pin 18 Transferred Pin 18 Transferred
Pin 19 Request Pin 19 Request
Pin 20 GND 24 VDC for request / transferred
(galvanic isolation)
Pin 20 GND 24 VDC

37
Technical Data
Siemens Signal Interface
Signal Curve
1
.
Af
ter sw
i
tc
hi
ng on t
h
e stat
i
on
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n transports
PCB to the transfer position
Belt n running Belt n+1 stopped
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
is ready to receive PCBs
0
0
1
0
2. The PCB transfer has started
Transport direction
Belt n Belt n+1
PCB sensor
Station n transfers
PCB to Station n+1
Belt n running Belt n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects
PCB from station n
1
0
1
0
3. PCB is transferred
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n has
just transferred the PCB
Belt n stopped Belt n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1 expects PCB
from station n, but PCB
has not yet arrived.
0
1
1
0
PCB sensor
4. PCB transfer is complete
Transport direction
Belt n Belt n+1
PCB sensor PCB sensor
Station n
Belt n stopped Belt n+1 running
Request
Transferred
Permission
Arrived
Request
Transferred
Permission
Arrived
Station n+1
PCB arrived
0
0
0
1