00197089-02_AI_EA-Verl_X-Serie_S_de_en.pdf - 第74页

Installation Final Wo rk: 3.6.1 Teaching the PCB Sensors (SW70x) 74 Extension Input/Output Conveyor and Hand Guard Ein-/ 3.6 3 . 6 F in a l W o r k : Final Work: ► If you have dismantle d the nozzl e reject station, fix …

100%1 / 80
Installation
3.2.8 Output Conveyor – Conveyor Side D Fitting the Hand Guard
Extension Input/Output Conveyor and Hand Guard Ein-/Ausgabebandverlängerung und Eingreifschutz 73
3.5
3.5 Fitting the Hand Guard
Fitting the Hand Guard
NOTICE
Second person
You may need to enlist the help of a second person for this job.
Fix the hand guard into place on the machine, using
the 4 fastening screws (1). (washer M6, screw
[03042571-xx] M6x10)
Without PCB barcode:
If no PCB barcode has been fitted, this flap must be
screwed into place. Proceed as follows:
Make sure that the two buffers (2) are fitted.
Fix the flap to the two corners (1) using the screws
provided (3).
The installation of the hand guard is completed.
NOTICE
With PCB barcode:
If a PCB barcode is fitted into the hand guard, make sure you secure the flap with a Schmersal
switch.
Read the "PCB Barcode" assembly instructions.
Installation
Final Work: 3.6.1 Teaching the PCB Sensors (SW70x)
74 Extension Input/Output Conveyor and Hand Guard Ein-/
3.6
3.6 Final Work:
Final Work:
If you have dismantled the nozzle reject station, fix it back into place.
If you have loosened the clamp, restore the clamping function.
If you have loosened the fixed side, fix it back into place.
Check the PCB sensors and calibrate these if needed (see section "3.6.1 Teaching the PCB Sensors
(SW70x)" [ 74]).
Configure the installation (or removal) of the extension in the Sirio software.
3.6.1
3.6.1 Teaching the PCB Sensors (SW70x)
Teaching the PCB Sensors (SW70x)
Whenever you manually loosen the conveyor sides, you also need to reteach the light barrier sensors.
This is required because the light intensity depends on the conveyor width. Without teaching, the con-
veyor will show boards which are not present, preventing the conveyor from being referenced.
Teaching is performed automatically during operation.
Procedure
Switch over to the activity level "Service (customer)"
(or better still).
Select .
Select .
Select Conveyor inputs/outputs.
Installation
3.6.1 Teaching the PCB Sensors (SW70x) Final Work:
Extension Input/Output Conveyor and Hand Guard Ein-/Ausgabebandverlängerung und Eingreifschutz 75
Select Laser light barrier at conveyor lane 1, enable
Teach board sensors and press the Start button on
the machine.
Disable this function again afterwards.
For DC: select Laser light barrier at conveyor lane 2,
enable Teach board sensors and press the Start but-
ton on the machine.
Disable this function again.