00198481-01_Technical_Training_E_by_DEK_EN.pdf - 第41页

5 Gantry Systems 5.2 Camera System Technical Training E by DEK 12/2017 41 5.2.4 Analysis Common error list Fig.4: Station Software Menu for Camera Diagnostic functions Error Description Possible Cause Action No image ● …

100%1 / 114
5 Gantry Systems
5.2 Camera System
40 Technical Training E by DEK 12/2017
5.2.2.2 Board Stop Sensor
Board Stop Function
As standard a reflective opto sensor is used.
1. Camera
2. Camera Mounted Board Stop
3. Board at Stop Sensor
5.2.3 Overview Camera's Electrical System
5.2.3.1 Camera System Rotary drive - Electrical Overview
5 Gantry Systems
5.2 Camera System
Technical Training E by DEK 12/2017 41
5.2.4 Analysis Common error list
Fig.4: Station Software Menu for Camera Diagnostic functions
Error Description Possible Cause Action
No image
Mechanical
Electrical
Check voltages
Check camera
(defect or damaged)
Check all cable connections
Check firewire cable and card
Camera has problems
finding the home position
Damaged or defect home
sensor
Check /exchange home sensor
Sporadic offsets Camera is not positioned
correctly or mechanical
damage to gantry system
Check belt tensions
Check pulleys and gears
Check camera (fixed correctly)
Check camera
5 Gantry Systems
5.2 Camera System
42 Technical Training E by DEK 12/2017
5.2.5 Part Exchange / Settings / Calibrations
Camera System
Parts Exchange
Tools/ Setting Calibration
Camera
Vision Height
Camera Reference Position
Board Stop X Offset
Vision Calibration
Offset Calibration
Board Stop Sensor Adjust Sensor Sensitivity
Drive Belts Belt tension tool
Belt Tensions
X-Axis Front rail Parallelism
Camera Reference
Vision Calibration
Offset Calibration
Motors
Camera Reference
Vision Calibration
Offset Calibration
For further details please refer to the technical reference manual.
5.2.6 Maintenance
Maintenance tasks (For details refer to technical reference manuals).
Maintenance content Interval Requirement
Camera X Linear Bearing Guide (Rotary) Daily IPA wipes
3 monthly
THK AFB grease
Grease gun
Check condition and belt tension drive belts 3 monthly