00195374-0202_AI_LBO-D1D2_DE+EN.pdf - 第37页

Long bo ard option 2 Assembly instructions Long board op tion SIPLACE D1 / D2 06/2007 Edition 37 2 Assembly instructions Long board option SIPLACE D1 / D2 2.1 Description of the functions The units supplied are preass em…

100%1 / 70
1 Montageanleitung Option Lange Leiterplatte SIPLACE D1 / D2 Lange Leiterplatte
Ausgabe 06/2007
36
1.15 Lage der Inkpunkte
Alle Inkpunkte müssen im Überlappungsbereich der Leiterplatte sichtbar sein. 1
zulässige Inkpunkt-Positionen: 1
1
1
1
1
1
1
1
Long board option 2 Assembly instructions Long board option SIPLACE D1 / D2
06/2007 Edition
37
2 Assembly instructions
Long board option
SIPLACE D1 / D2
2.1 Description of the functions
The units supplied are preassembled for installation in PCB conveyors with stationary conveyor
side wall on the right (see drawings Chapter 2.11). 2
If the machine has the stationary conveyor side wall on th
e left, some modifications must be made
to the units (for the drawings, see Chapter 2.11). 2
2.2 Parts required
2.2.1 Retrofit kit
Long Board Option D1,D2 Single conveyor:
00119872-xx
Dual conveyor:
00119873-xx
LBO D1/D2 03049213-xx 1x 2x
1x Stopper process.area 1 00371907-xx
1x Assembling gauge LBO 03049211-xx
Long Board Option (1 licence) 00373251-xx 1x 1x
Assembly instructions Long board option D1/D2 00195374-xx 1x 1x
2
2.2.2 Tools and consumables required
Set of hexagon socket spanners
Diagonal cutter
–Torch
Cable ties.
2
2 Assembly instructions Long board option SIPLACE D1 / D2 Long board option
06/2007 Edition
38
2.3 Basic principles
Step 1
Step 2
Placement by
area 1 and 2
(overlapping area)
Only step 1
Only step 2
Step 1
Step 2
Placement by
area 1 and 2
(overlapping area)
Only step 1
Only step 2
Input-
conveyor
Placement-
area 1
Output -
conveyor
Additional-
stopper
Transport
direction
Accessible
placement area
450mm
Step 1
Additional-
stopper
Transport
direction
Accessible
placement area
450mm
Step 2
At each placement area 2 stop positions can
be approached (stepping mode)
Step 1 = PCB moves to laser stopper position
Step 2 = PCB moves to the additional stopper position
2
With long boards, the PCB in the processing area is first stopped and placed at the laser light bar-
rier. It is then advanced as far as the additional sto
pper and placed. 2
Standard laser
light barrier
Additional stopper
(optional)
Standard laser light barrier
Optional PCB stopper
3-segment conveyor belt:
input belt, placement belt
output belt
Transport
direction
Processing
area
Input conveyor Output conveyor
2