3-15 3 Starting and ending pr oduction 3 . 5 R e t r y T h e [ R e t r y ] t a b s c r e e n d i s p l a y s t h e h i s t o r y o r t h e p a s t 1 0 0 e r r o r s . Monitor: Retr y 24 3 0 8 - M 0 -0 0 3 . 6 F i d u c i…

3-14
3
Starting and ending production
3.4 Alignment
The [Alignment] tab screen shows the offset amount of each head calculated from the recognition results
obtained during automatic operation, as well as error numbers.
Monitor: Alignment
24307-M0-00
• Head No.
Shows the head No. used in the machine. The recognition results of the head No. used in the sequence that starts from
the current pickup are displayed. Note that the display is made after the camera image recognition has completed.
• Parts No.
Shows the number of the component picked up by the head and recognized with the camera.
• Feeder Set No.
Shows the feeder set number of the component picked up by the head and recognized with the camera.
• X, Y, R
Displays the offset amount of each head calculated from the recognition results obtained during automatic operation.
This offset is the positional deviation from the center of the nozzle.
• Error No.
Shows an error number when the head fails to recognize a component.

3-15
3
Starting and ending production
3.5 Retry
The [Retry] tab screen displays the history or the past 100 errors.
Monitor: Retry
24308-M0-00
3.6 Fiducial
The [Fiducial] tab screen shows the recognition results of fiducial marks such as "Board, Block", "2 Point Local"
and "Point" fiducial marks.
Monitor: Fiducial
24309-M0-00
• Align X, Y, R
Shows the difference between the recognition results and the board data input values, by plus or minus values.
• Align Ratio
Shows the rate of expansion of the board, calculated by using the X, Y and R offset values.
• Result
Shows the recognition results as a "Pass" or "Unfinished ". The "Unfinished" message changes to "Pass" after the mark has
been recognized successfully.

3-16
3
Starting and ending production
3.7 Badmark
The [Badmark] tab screen shows the recognition results of badmarks such as "Board, Block" and "Local"
badmarks.
Monitor: Badmark
24310-M0-00
• X, Y
Shows the board data input values (by taking block offset amount into account).
• Result
Makes an "OK" or "NG" decision based on the badmark recognition result.
OK : Work is performed when no badmark is recognized.
NG : Work is not performed when a badmark is recognized.