00198610-01_VD_712.0_R18-2_DE_EN.pdf - 第31页

Station Software 71 2.0 (R18 - 2) / Versio n Description 11/2018 Edition 31 7 Restrictions For details conce rning possible machi ne configurations , please consult the latest version of th e machine specificati on. Rest…

100%1 / 84
Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
30
6.4 ASM Traceability Version 5.5
Software version 5.5 of ASM Traceability supports the SIPLACE X-series, X-series S,
SX-series, DX-series, CA-series and TX-series placement machines.
Compatible mode: SIPLACE Traceability 4.x
NOTICE
A detailed description can be found in the "Traceability User Guide".
Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
31
7 Restrictions
For details concerning possible machine configurations, please consult the latest version of the
machine specification.
Restrictions to features in previous versions can be found in the Station Software V7xx Feature
Description, item no. [00197741-xx].
Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
32
8 Corrected Errors
712.0 Station Software
The 712.0 station software version contains all error corrections of the previous 7xx versions.
Additionally, the following errors have been corrected in this version:
Error no. Error description
D1-142591801 An incorrect conveyor width was set after reboot.
D1-145486748 Various conveyor errors.
D1-146654832 During the height reference run, a nozzle was expected that was missing. The
nozzle could not be provided at the current activity level.
D1-148088101 The CPP placement head removed a component that was already placed by
the Twin VHF placement head.
D1-148126901 Width adjustment was performed during running production on a SIPLACE
TX2i placement machine.
D1-149428701 Night run with cyclic board transport stopped: disturbed CAN communication,
channel 1. Error message Placement status is unknown: Gantry 1,
Segment 1
was displayed.
D1-152642401 The Tray view automatically jumped to level 1 after the WPTC was confirmed.
D1-152854501 The conveyor did not function during machine endurance run.
D1-153279801 The stations within one line displayed different states (productive/blocked).
D1-153508601 Errors could not be selected in the error statistics view.
D1-154092217 Undefined hardware error after downloading Application 1; 5 DP axes without
Application 1.
D1-154781809 Stop threshold = 0 was ignored.
D1-155009601 At error 33263 Connection between GigE interface card in the
PC and the camera interrupted (252), the GUI did not display which
camera or gantry was affected.
D1-155170101 Glass plate with fiducials could not be calibrated with the SST47 board
camera.
D1-155523201 X4 S placement machine: FCCS digital – in PA1, the stop position of the tray
had a 5 cm back shift. The fiducials could not be recognized.
D1-155597201 Location 2 could not be approached by position correction.
D1-155619501 Stopping the production took too long.
D1-156262534 The software hung up and the module had to be restarted.
D1-156809701 The machine stopped during the 2h run (first board) after about 4 minutes
without any error message.