00198610-01_VD_712.0_R18-2_DE_EN.pdf - 第34页
Station Software 71 2.0 (R18 - 2) / Versio n Description 11/2018 Edition 34 711.1 SP1 Error no. Error description D1 - 140512109 Automatic program do wnload via barco de: machine needed to be emptied when using smart pin…

Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
33
D1-157648601 After the table was removed and inserted, the feeder speed of the Xi Feeder
changed automatically.
D1-158062753 Extended Vision dump file was not stored.
D1-158064501 After starting the FCCS, the gantry never moved to the FCCS plate to start the
calibration.
D1-158433701 The Leveling assistant could not be performed.
D1-158465849 Leveling assistant error.
D1-159122707 The ACT measurements were not successful, because the distance check
failed.
D18495-4001 The XML file generated by Traceability had the wrong start time.
Table 8-1: Corrected errors station software version 712.0
711.1 SP2
Error no. Error description
D1-155313201 When a new job was downloaded all the feeder signals were off.
D1-157668741 eSW: Error message 30470 Either collision of two gantries or
axis hit bumper at end of driving range
.
D1-157715301 When trying to inspect a placement position, no image was displayed.
D1-157719277 A splice was not detected.
D1-157830601
D1-157926708
eSW: Error when checking the motor current for width adjustment.
D1-157851214
D1-158056019
eSW: Sporadically, the error messages 30399 Table 1: Unexpected
reboot from subsystem detected or 34921 Feeder: Input
voltage too low
were displayed.
D17819-36801
D18551-2301
D18495-4701
D18526-6601
D1-58354825
After some days of production, teaching components or opening dump files
got very slow.
D18093-37005 The whispered data did not fit to the board.
Table 8-2: Corrected errors station software version 711.1 SP2

Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
34
711.1 SP1
Error no. Error description
D1-140512109 Automatic program download via barcode: machine needed to be emptied
when using smart pins although the pins were in the same position in both
programs.
D1-144918301 The binder of the linear feeder did not open at the first pickup event.
D1-145486749 eSW: conveyor error messages 30007 Cannot open file and 35336 An
unknown conveyor control unit has been detected after machine
start.
D1-149326501 During production, there was a message that the "Application has to be
closed.
D1-150606549 In case of contactless pickup, the z height was not re-taught, and the feeder
pocket was not measured again after a foil torn.
D1-150924808 Improvement of the manual Pin 1 check to be able to recognize low-contrast
structures.
D1-151189122 eSW: Vacuum for vacuum tooling was not turned on automatically during
recovery placement mode.
D1-151304001
D1-151342257
D1-152045605
After having continued the mapping after a Vision error the mapping
component was lost, and the mapping could not be finished.
D1-151804201 In the Feeder Parameter view, the information "spacer is needed" was
displayed for components with contactless pick-up although current feeders
did no longer need a spacer.
D1-152045605 It was not possible to teach a pickup offset of more than 1 mm for a WPC tray.
D1-152513701 Picking up from 2 special feeders with undefined busy time led to performance
loss as the feeders did not answer quick enough.
D1-152745201
D1-153297807
D1-153360401
D1-154070049
Sporadic problems during the benchmark placement (SX2 with TH).
D1-152748201 Virtual PCB stack: a multi panel board could not be placed.
D1-152854543 After having moved to the nozzle changer position on location 2 in the teach
menu, the software stopped, and the machine had to be switched off.
D1-153217601 37800 [Twin Head, gantry 1] Machine stopped due to too many
repetitive errors.
D1-153325901 PPW 1_L could not be calibrated.
D1-153333101 TX2 V2 with CPP/C&P20 P2 (nozzle changer for CPP is 3.65 mm lower):
there was a warning during calibration of the nozzle changer that the 3 mm
border was exceeded.
D1-153360489 The virtual keyboard was in the background of the input window of the bug
reporter.
D1-153368126 Error message 32507 Product change: Finishing previous
product prior to setup change and no more boards got into the
machine.
D1-153466646 When adjusting the pickup offset, the gantry was moving 300 mm towards the
conveyor instead of going to the pickup position of the WPC.

Station Software 712.0 (R18-2) / Version Description 11/2018 Edition
35
D1-153552201 There was a problem when synchronizing SMEMA and whispering data
between adjacent machines.
D1-153630802 Error message 30450 Unspecified hardware error was displayed for
each camera but there was no problem at the machine.
D1-153875301 eSW: there was a problem with the transition between the SIPLACE and
AYSY conveyors.
D1-153989601 Changing the conveyor width led to error message Unexpected software
malfunction - the application has to be closed
.
D1-154055101 The firmware update for the C&P20 pressure regulator could not be done.
D1-154075385 After having downloaded the conveyor BIOS, the subsystem could not be
activated.
D1-154379501 The service symbol was not active after the machine started.
D1-154598802 In stand-alone mode, old jobs could not be deleted any longer.
D1-154781809 Threshold = 0 had no effect: the machine stopped although no threshold was
defined within Setup Center.
D1-155170101 The fiducial plate position of the SST47 could not be calibrated.
D1-155177302 The machine reported a yellow board with an unknown placement state, but
this position could not be checked within the manual operations because just a
grey field was displayed.
D1-155243901 The calibration of the offset between SST47 and SST34 failed.
D1-155371401 Sporadically, the station software stopped during placement with error
message
32602 The software has stopped unexpectedly
.
D18199-16132 Better handling within the station software for the selection of component
shapes that shall be taught.
D18272-5888 eSW: A 440 mm board did not reach the placement area in an X4 S
placement machine with short input conveyor.
D18445-3801 Sporadically, the station software stopped during placement with error
message
32602 The software has stopped unexpectedly
.
D18459-1601 The machine displayed an X-axis error 30341: Position is out of
range
.
D18474-3601 Special FFI feeder brought error message 40007 out of components
although feeder was filled up with 1200 components.
D18505-3253 Sometimes component teaching slowed down the computer.
D18541-2515 Chuck fiducials CA4: If the vacuum tooling fiducials were not used for
recalibration, a dual gantry measurement must be done.
D18570-1501 The machine stopped during placement without error message.
D18585-2817 Moving a gantry to service position did not work and the error message
32535
Checking nozzle configuration: CPP Head, gantry1 was
displayed.
Table 8-3: Corrected errors station software version 711.1 SP1