雅马哈贴片机吸嘴健康自动检查功能.en.zh-CN.pdf - 第11页

ProductEngineeringDivision SMTSection IMOperations YAMAHAMOTORCO., LTD MDOC‑SOFT50394 11/22 No. 21 ItemName [Alignment]X‑Upper limit[mm] Explanation Valueof[Machine]‑[MachineData]‑[PickupMACS][NozzleMACS]…

100%1 / 22
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,LTD
MDOC‑SOFT50394 10/22
7
VacuumCheck
ResultofVacuumCheck.
([OK]or[NG].Emptywhendoesnotperformed)
ResultofNozzleTipDirtCheck.
([OK]or[NG].Emptywhendoesnotperformed)
ResultofNozzleBuffingCheck.
([OK]or[NG].Emptywhendoesnotperformed)
ResultofNozzleShapeCheck.
([OK]or[NG].Emptywhendoesnotperformed)
ResultofNozzleAlignmentCheck.
([OK]or[NG].Emptywhendoesnotperformed)
Resultofvacuumlevel.
(Onlywhenvacuumcheckisexecuted)
Valueof[Machine]‑[MachineData]‑[Head]‑[VacuumLevel]‑
[LowLevel].
(Onlywhenvacuumcheckisexecuted)
Valueof[Machine]‑[MachineData]‑[Head]‑[VacuumLevel]‑
[HighLevel].
(Onlywhenvacuumcheckisexecuted)
DetectionRate(%)=(VacuumLevel‑LowLevel)/(HighLevel‑
LowLevel)*100
(Onlywhenvacuumcheckisexecuted)
DetectionValueof[Machine]‑[SpecificationInformation]‑[Schedule
Specification]‑[VacuumCheck]‑[ErrorDetectionRate].(Only
whenvacuumcheckisexecuted)
Measureresultofnozzletiplength.
(OnlywhenNozzleShapeCheckisexecuted)
“Thedesignvalueunderanozzletiplength(um)”+“Theerror
underanozzletiplength(um)”valueof[Machine][Specification
Information]‑[SideViewCameraSpec][NozzleBasicSetting].
(OnlywhenNozzleShapeCheckisexecuted)
“Thedesignvalueunderanozzletiplength(um)”‑“Theerror
underanozzletiplength(um)”valueof[Machine][Specification
Information]‑[SideViewCameraSpec][NozzleBasicSetting].
(OnlywhenNozzleShapeCheckisexecuted)
MeasureresultofnozzlegapX
(OnlywhenNozzleAlignmentCheckisexecuted)
8
TipDirtCheck
9
BuffingCheck
10
ShapeCheck
11
AlignmentCheck
12
[Vacuum]VacuumLevel
13 [Vacuum]PickLowLevel
14 [Vacuum]PickHighLevel
15 [Vacuum]DetectionRate
16 [Vacuum]Error
Rate
17
[Shape]Measurement[um]
18 [Shape]UpperLimit[um]
19 [Shape]LowerLimit[um]
20
[Alignment]X‑gaps[mm]
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,
LTD
MDOC‑SOFT50394 11/22
No.
21
ItemName
[Alignment]X‑Upper
limit[mm]
Explanation
Valueof[Machine]‑[MachineData]‑[PickupMACS][NozzleMACS]‑
[CorrectLimitX(mm)].
(OnlywhenNozzleAlignmentCheckisexecuted)
MeasureresultofnozzlegapsY.
(OnlywhenNozzleAlignmentCheckisexecuted)
Valueof[Machine]‑[MachineData]‑[PickupMACS][NozzleMACS]‑
[CorrectLimitY(mm)].
(OnlywhenNozzleAlignmentCheckisexecuted)
22
[Alignment]Y‑gaps[mm]
23 [Alignment]Y‑Upper
limit[mm]
*Exampleoflogfile
V1.00,MultiLanguage
EN,Date,TableNo,HeadNo,NozzleType,Nozzletation,ExecuteTrigger,VacuumCheck,TipDirtCheck,Buffing
Check,hapeCheck,AlignmentCheck,[Vacuum]VaccumLevel,[Vacuum]PickLowLevel,[Vacuum]PickHigh
Level,[Vacuum]Detectionate,[Vacuum]ErrorDetectionate,[hape]Measurement[um],[hape]Upper
Limit[um],[hape]LowerLimit[um],[Alignment]X‑gaps[mm],[Alignment]X‑Upper
limit[mm],[Alignment]Y‑gaps[mm],[Alignment]Y‑Upperlimit[mm]EN,2015/03/1512:00:00,A,1,
TYPE‑301,1,NHC,OK,OK,OK,OK,OK,200,180,200,100,30,2000,2040,1960,0.100,0.150,0.200,0.160
EN,2015/03/1512:01:00,A,3,TYPE‑301,3,CH,,NG,OK,OK,OK,,,,,,2000,2040,1960,0.200,0.150,0.100,0.160EN
,2015/03/1512:02:00,B,8,TYPE‑302,28,UTL,OK,,,,,190,104,190,100,28,,,,,,,
4.SettingMethod
4.1MachineSetting
4.1.1InstallationSetting
Set[Machine]‑[Setting]‑[MachineInformation]‑[InstallationSetting]‑[NozzleHealthCheck]
to“Use”.
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,
LTD
MDOC‑SOFT50394 12/22
Theconditionsforusing[NozzleHealthCare]functionareasfollows.▲4
1.YSM40R
2.SuperHi‑SpeedHead
3.Enable[AutoNozzleChange]function
Set[Vmspec]‑[MachineVariationSetting]‑[NozzleStation]to“Use”.Set
[Vmspec]‑[NozzleStation]‑[Use/NotUse]to“Use”.
4.Set[Vmspec]‑[NozzleStation]‑[NozzleFreeLayoutSetting]to“Use”.
4.1.2Checkingconditions
NozzleHealthCheckisperformedbasedonthemachinesetting.
1)VacuumCheck
Errordetectionrateofeachmachinemodelisasthefollowingsettingvalues.OnYS88,
YS100,YS12SeriesYG12Series,YS24(X)series
[Machine]‑[Setting]‑[SpecificationInformation]‑[ScheduleSpecification]‑[Vacuum
Check]‑[ErrorDetectionRate]
OnYSMSeries▲2,3,4
[Machine]‑[Setting]‑[SpecificationInformation]‑[MountNozzleSpecification]‑[Nozzle
Data]‑[ErrorDetectionRate(%)]