雅马哈贴片机吸嘴健康自动检查功能.en.zh-CN.pdf - 第19页

ProductEngineeringDivision SMTSection IMOperations YAMAHAMOTORCO.,LTD MDOC‑SOFT50394 19/22 7579 Abnormalnozzleshape detected. Thereissomethingwrongattachedonanozzle. Cleanorchangeit. 7580 Abnormalnoz…

100%1 / 22
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,LTD
MDOC‑SOFT50394 18/22
7576
AbnormalVacuum
Detected.
DetectionRate(%)islargerthanErrorDetectionRate(%).A
nozzlemaybeclogged.
・Cleanorchangethenozzleandshaft.
・ConfirmthevalueofErrorDetectionRateon[Setting]‑
[SpecificationInformation]‑[MountNozzleSpecification]
[NozzleData].
・ConfirmtheLowlevelandHighlevelof[Setting]‑
[MachineData]‑[Head]‑[VacuumLevel].
*Fordetailsof"DetectionRate"and"ErrorDetectionRate",
refertothe[Detail]tab.
‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑‑
"DetectionRate"means"cloglevel"ofanozzle,
comparedtothedifferencebetween"MaxVacuumLevel"
and"MinVacuumLevel"as100.
DetectionRate(%)=(CurrentVacuumLevel‑MinVacuum
Level)/(MaxVacuumLevel‑MinVacuumLevel)×100
VacuumLevel"meanshighlevel.
Theerroroccurswhen"DetectionRate"isover"Error
DetectionRate".
"MinVacuumLevel"meansLowLevel,and"Max
7577
Nozzletipdirtdetected. Abnormalitydetectedonthetipofanozzle.It
maybeuncleanordamaged.
7578
AbnormalnozzlebuffingThereissomethingwrongwiththenozzlebuffing.
detected.
Thebuffingmaybeunclean,sticky,orjammed.
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,LTD
MDOC‑SOFT50394 19/22
7579
Abnormalnozzleshape
detected.
Thereissomethingwrongattachedonanozzle.
Cleanorchangeit.
7580
Abnormalnozzle
alignmentdetected.
Misalignmentofnozzletippositionisoverthecorrection
limit.
Thenozzlemaybedamaged,unclean,orskewed.
7581
UnabletoperformnozzleItisnecessarytoreadboarddata,when"ManualNzlChg"
healthcheck.
isselected.
Readboarddata,or
Select"AutoNzlChg"on[Machine]‑[MachineData][Head]‑
[HeadOffset].
7584
Boarddatahasbeen
edited.
Saveandreloadtheboarddatatoapplythechanges.
ProductEngineeringDivision
SMTSection
IMOperations
YAMAHAMOTORCO.,LTD
MDOC‑SOFT50394 20/22
7585
NozzleHealthCheck
failed
Checktheconditionsbelowandtryitagain.
・Execute[Unit]‑[Head]‑[NozzleChange]andconfirm
thenozzleissuccessfullychanged.
・Execute[Unit]‑[Head]‑[CleaningBlow]andconfirm
thecleaningblowissuccessfullyperformed.
・Settingsofeachnozzlecheck(*)arecorrect.
(Fordetails,refertotheoperationmanual.)
*“Eachnozzlecheck”meansthefollowingitemsofNozzle
HealthCheck.
・VacuumCheck
・NozzleTipDirtCheck
・NozzleBuffingCheck
・NozzleShapeCheck
・NozzleAlignmentCheck
7590
NozzleHealthCheck
ExecutionError
UnabletoexecuteNozzleHealthCheckwith[boarddata
nozzle]becausetheboarddatahasanerror.
Reloadtheboarddataandremovethecauseoftheerror.
7591
NozzleHealthCheck
ExecutionError
UnabletoexecuteNozzleHealthCheckwith[boarddata
nozzle]becauseboarddataisnotread.
Readboarddata.