00197674-01-UM-E-Series-EN-05-2015.pdf - 第200页
5 Working with the machine User manual SIPLACE E 5.2 Controls and displays From software version SC 708.0 05/2015 Edition 200 5.2.2 Controls on the machine's operator panels All the controls can be reached by a 1.40…

User manual SIPLACE E 5 Working with the machine
From software version SC 708.0 05/2015 Edition 5.2 Controls and displays
199
5.2 Controls and displays
5.2.1 Overview
5
Fig. 5.2 - 1 Controls and displays
5
(1) Main switch (5) Stop button (black)
(2) Start button (white) (6) LCD touchscreen
(3) EMERGENCY STOP button (7) Indicator lamps with buzzer
(4) Keyboard (T) Direction of PCB transport
(1)
(4)
(3)
(2)
(6)
(7)
(5)

5 Working with the machine User manual SIPLACE E
5.2 Controls and displays From software version SC 708.0 05/2015 Edition
200
5.2.2 Controls on the machine's operator panels
All the controls can be reached by a 1.40 m tall person. There is a monitor and a keyboard on both
sides of the machine.
The start and stop buttons are located near the keyboard. The on-screen dialog will occasionally
prompt you to activate certain actions using buttons, and this arrangement will make it easier for
you both to activate and to interactively control these actions.
Main switch 5
The main power switch is used to switch the power supply to the machine on and off.
5
Stop button (black) 5
This button is used to stop the machine.
Start button (white) 5
This button starts the machine after it has been switched on or after faults have been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the changeover tables, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
LCD touchscreen 5
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place
-
ment machine.
DANGER
Lethal voltages!
Some parts inside the machine carry potentially lethal voltages - even when switched off
at the main power switch.

User manual SIPLACE E 5 Working with the machine
From software version SC 708.0 05/2015 Edition 5.2 Controls and displays
201
Keyboard 5
The keyboard is located beneath the monitor.
5
Optional indicator lamp with buzzer - three color (red/yellow/green) 5
The sequence of colors of the indicator lamps is red - yellow - green. These lamps are used to
signal operating statuses and malfunctions of the machine. The buzzer indicates when an alert
has occurred. See also Section 5.8 on page 218.
Indicator lamp with buzzer - two color (white/green) - optional 5
The sequence of colors of the indicator lamps is white - green. These lamps are used to signal
operating statuses and malfunctions of the machine. The buzzer indicates when an alert has oc
-
curred. See also Section 5.8 on page 218.
CAUTION
Risk of collision on the monitor with keyboard
When working on the changeover table, there is risk that you could collide with the monitor
and keyboard.
Turn the monitor and keyboard away to the side.
Make sure that you are not under the monitor and keyboard with your head.