00197674-01-UM-E-Series-EN-05-2015.pdf - 第303页

User manual SIPLACE E 7 Maintenance From software version SC 708.0 05/2015 Edition 7.2 Maintenance o n Base Machine 303 7 7 7 a) This value is for 3 shift operation (7500 hours of operation ). Longer intervals can be pla…

100%1 / 308
7 Maintenance User manual SIPLACE E
7.2 Maintenance on Base Machine From software version SC 708.0 05/2015 Edition
302
7.2 Maintenance on Base Machine
7
7
Base machine Every 6
months
Every 12
months
Checking the Fans on the MGCU
X
Checking the safety features on machines
X
Checking and Cleaning/Replacing (if required) the Compressed Air Filter
X
Cleaning/Replacing the Head Exhaust Air Filter
X
Greasing and clean the X axis guide bearing
X
Cleaning the Linear Guides of the X Axis
X
Grease and clean the Y axis guide bearing
X
Cleaning the Linear Guides of the Y Axis
X
Cleaning the X Axis Scale
X
Cleaning the Y Axis Scale
X
Cleaning the Protective Covers
X
Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the
Protective Covers
X
Replace the loose bearing lubrication system X axis and Y axis (if pres
-
ent)
X
Grease and clean the X and Y axis guide bearing
X
Conveyor Every 6
months
Every 12
months
Cleaning and Preserving the Conveyor
Hexagonal shafts
Linear guide rails
Ball screws
Guide shaft
X
User manual SIPLACE E 7 Maintenance
From software version SC 708.0 05/2015 Edition 7.2 Maintenance on Base Machine
303
7
7
7
a) This value is for 3 shift operation (7500 hours of operation). Longer intervals can be planned for other operation setups.
Component Docking Unit Every 6
months
Every 12
months
Function Test of Tape Cutter
X
Greasing the Tape Cutter
X
Greasing the Cutting Blade
X
Greasing the COT Insert
X
Greasing the Locator Bearing on the Component Trolley for SIPLACE
SmartFeeder E
X
Optical Systems Every 6
months
Every 12
months
Cleaning the IC and FC Cameras
X
Cleaning the PCB Barcode Scanner (if availible)
X
Cleaning and Checking tasks
Vacuum pump
Every 6
months
Every 12
months
Checking/Replacing the Filter Insert
X
a
7 Maintenance User manual SIPLACE E
7.3 Maintenance on SIPLACE CP14 P From software version SC 708.0 05/2015 Edition
304
7.3 Maintenance on SIPLACE CP14 P
7
SIPLACE CP14 Every 6
months
Every 12
months
Maintenance Pressure Control Valve
X
Cleaning the Z Axis
X
Oiling the DP Segment Guide
X
Oiling the Z Axis Linear Guide
X
Oiling the DP Driver Bearing
X
Checking/Replacing the Vacuum-Conducting Parts
Reflecting ring and cover
or 7
Holding circuit and silencer
X
Cleaning the Raceway and the Jaw
X
Replacing the Filter Disks
X
Checking/Cleaning/Replacing the Switching Disks
X
Cleaning the Component Sensor
X