3MAINTENANCE__O.pdf - 第127页

3.5 Offset Teaching ( 6 ) To exit from the master head offset teaching session , select the [ INDEX THE TURRET ( + ) [ MOVE ] ] key and press the [ MOVE ] button to move the master head to the placement station . ( 7 ) D…

100%1 / 201
3.5
Offset
Teaching
COMP
.
REC
.
COMM
.
/
DSBL
This
label
appears
when
DISABLE
is
set
in
the
text
box
of
the
label
DRY
CYCLE
MODE
at
the
TEST
MODE
display
.
In
this
case
the
result
of
each
teaching
operation
is
not
reflected
on
offset
data
.
LINEAR
MEASURE
/
DSBL
This
label
appears
when
DISABLE
is
set
in
the
text
box
of
the
label
LINEAR
MEASURE
MODE
at
the
TEST
MODE
display
.
In
this
case
,
the
result
of
each
teaching
operation
is
not
reflected
on
offset
data
.
Procedure
for
Master
Head
Offset
Teaching
(
1
)
Select
the
[
INDEX
THE
TURRET
(
+
)
[
MOVE
]]
or
[
INDEX
THE
TURRET
[
-
]
[
MOVE
]]
key
and
press
the
[
MOVE
]
button
to
move
the
No
.
1
head
to
the
placement
station
.
(
2
)
Attach
the
master
head
to
the
No
.
1
head
position
.
Attach
the
jig
nozzle
(
master
nozzle
)
to
the
No
.
1
nozzle
position
on
the
master
head
.
Note
:
Do
not
attach
the
jig
nozzle
to
any
of
the
Nos
.
2
-
5
nozzle
positions
.
(
3
)
Orient
the
master
nozzle
to
the
3
o
clock
direction
through
the
manual
operation
.
(
4
)
Adjust
the
height
of
the
master
nozzle
to
UL
Level
.
(
5
)
Select
a
teaching
mode
and
perform
the
teaching
operation
.
When
the
[
HEAD
POSITION
&
LEVEL
TEACH
[
MOVE
]
]
key
is
selected
and
the
[
MOVE
]
button
is
pressed
,
teaching
operation
is
performed
on
X
/
Y
data
(
head
position
)
in
L
level
L
level
and
L
data
(
level
in
height
direction
)
of
H
level
.
When
the
[
LEVEL
TEACH
[
MOVE
]]
key
is
selected
and
the
[
MOVE
]
button
is
pressed
,
teaching
operation
is
performed
on
L
level
and
L
data
(
level
in
height
direction
)
of
H
level
.
When
the
[
HEAD
POSITION
TEACH
[
MOVE
]
]
key
is
selected
and
the
[
MOVE
]
button
is
pressed
,
teaching
operation
is
performed
on
X
/
Y
data
(
head
position
)
in
L
level
.
Ref
.
:
L
data
(
level
)
offset
value
in
height
direction
is
stored
in
memory
as
Master
Nozzle
(
H
)
Offset
=
Master
Nozzle
(
L
)
Offset
-
400
(
Unit
:
0.01
mm
)
.
3
36
9803
-
001
ACP
01
EIN
3
-
36
3.5
Offset
Teaching
(
6
)
To
exit
from
the
master
head
offset
teaching
session
,
select
the
[
INDEX
THE
TURRET
(
+
)
[
MOVE
]
]
key
and
press
the
[
MOVE
]
button
to
move
the
master
head
to
the
placement
station
.
(
7
)
Detach
the
master
nozzle
and
head
.
(
8
)
When
errors
are
found
through
teaching
operation
,
the
number
of
errors
appears
on
the
[
TEACH
ERR
DATA
#
]
key
.
When
this
key
is
pressed
,
the
following
display
appears
on
the
screen
enabling
checking
of
error
contents
.
<
ERR
0
R
INFOMATIOH
(
T
£
ACH
)
>
10000041
rayipfiai
Fig
.
3
-
31
Re
-
attach
the
master
head
and
adjust
it
.
After
that
,
perform
teaching
operation
.
3
37
Q
8
n
^
-
nm
ACP
01
EIN
3
-
37
3.5
Offset
Teaching
3.5
.
4
P
.
E
.
C
.
Camera
Offset
Teaching
This
function
automatically
calculates
offset
values
X
Y
and
Z
of
the
P
.
E
.
C
.
Y
,
using
a
special
jig
P
.
C
.
B
.
and
feeds
back
the
calculated
values
as
the
offset
data
of
the
P
.
E
.
C
.
camera
.
(
Camera
3
)
and
the
camera
magnification
data
X
and
camera
When
the
[
P
.
E
.
C
.
CAMERA
OFFSET
]
key
is
pressed
at
the
OFFSET
TEACH
display
the
following
display
appears
on
the
screen
.
P
.
E
.
C
.
CAMERA
OFFSEI
IEACH
)
MODE
[
MOVE
]
U
.
23
X
Y
CALIBRATION
M
MARK
COORDINATE
40.00
m
Z
=
1
HEIA
X
9999
PEC
CAMR
MAG
.
X
0
.
oium
/
oixei
V
Y
jQJQjrn
9999
I
FIDUCIAL
MARK
PQSlIiON
IOVET
lAUIQ
TEACH
[
tiQVEl
1
X
/
Y
TABLE
QRlGll
mu
\
8
9
C
7
CALIBRATION
JiG
MARK
X
40
.
00
mm
5
6
4
ANDAPRESSPIHETfsEIUEV
.
3
2
1
RTN
EDIT
DATA
X
/
Y
TABLE
MOVE
:
SET
0
4911
Fig
.
3.32
When
the
above
display
is
opened
for
the
first
time
,
40.00
mm
(
default
)
is
automatically
set
in
the
data
boxes
of
the
labels
CALIBRATION
JIG
MARK
COORDINATE
X
and
CALIBRATION
JIG
MARK
COORDINATE
Y
.
Procedure
for
P
.
E
.
C
.
Camera
Offset
Teaching
(
1
)
Zero
the
X
/
Y
table
.
(
2
)
Place
the
jig
P
.
C
.
B
.
on
the
X
/
Y
table
.
(
3
)
Enter
parameters
in
the
data
boxes
of
the
labels
CALIBRATION
JIG
MARK
COORDINATE
X
and
CALIBRATION
JIG
MARK
COORDINATE
Y
as
follows
.
Select
the
data
boxes
of
the
labels
CALIBRATION
JIG
MARK
COORDINATE
X
and
CALIBRATION
JIG
MARK
COORDINATE
Y
and
enter
parameters
correctly
to
indicate
the
location
of
the
jig
P
.
C
.
B
.
calibration
mark
using
the
ten
-
key
pad
.
3
3 8
QRO
^
-
Om
ACP
01
EIN
3
-
38