4OM-1343-009_w.pdf - 第166页

3-18 AKFEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 424301 Cnvr . Positioning 2 Error The carrying in operation was not able to begin. ----- 424302 Cnvr . Positioning 2 Error The error was detected while …

100%1 / 235
3-17
AKFEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
424101 Cnvr. Positoining 2 Overtime
The PCB transport (carry in) from input cnvr. did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424102 Cnvr. Positoining 2 Overtime
The PCB transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424103 Cnvr. Positoining 2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr. Positoining 2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr. Positoining 2 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424107 Cnvr. Positoining 2 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424201 Cnvr. Positioning 2 PCB Detection
PCB’s were at inlet and outlet of cnvr.
Please continue the work after checking the PCB on a conveyor.
424202 Cnvr. Positioning 2 PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
Please continue the work after checking the PCB on a conveyor.
424203 Cnvr. Positioning 2 PCB Detection
No PCB on the cnvr. After positioning released, PCB could not be detected.
Please continue the work after checking the PCB on a conveyor.
424204 Cnvr. Positioning 2 PCB Detection
The conveyer entrance sensor detected PCB.
Please continue the work after checking the PCB on a conveyor.
424205 Cnvr. Positioning 2 PCB Detection
The PCB that has not been positioned exists.
Please position the PCB.
424206 Cnvr. Positioning 2 PCB Detection
An unsuitable detected state of the sensor is being kept.
When you remove the factor which the sensor has detected and there is a PCB in
the way of carrying in, please return on input buffer cnvr. and resume production by
WarmStart.
424207 Cnvr. Positioning 2 PCB Detection
The PCB was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a PCB can convey normally by manual conveyance.
0607-004
3.3 Conveyor
3-18
AKFEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
424301 Cnvr. Positioning 2 Error
The carrying in operation was not able to begin.
-----
424302 Cnvr. Positioning 2 Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
424303 Cnvr. Positioning 2 Error
The exhaust operation was not able to begin.
-----
424304 Cnvr. Positioning 2 Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
424305 Cnvr. Positioning 2 Error
The error was detected while the backup base was rising.
-----
424306 Cnvr. Positioning 2 Error
The error was detected while the backup base was descending.
-----
424307 Cnvr. Positioning 2 Error
Rise operation of a PCB locate stopper is not completed.
Please check a stopper.
424308 Cnvr. Positioning 2 Error
Downward operation of a PCB locate stopper is not completed.
Please check a stopper.
424309 Cnvr. Positioning 2 Error
The positioning change operation was not able to begin.
-----
424310 Cnvr. Positioning 2 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the PCB on a conveyor.
424311 Cnvr. Positioning 2 Error
The reversal positioning operation was not able to begin.
-----
424312 Cnvr. Positioning 2 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
424315 Cnvr. Positioning 2 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a PCB can convey normally by manual conveyance.
0607-004
3.3 Conveyor
3-19
AKFEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
425101 Output Cnvr. Overtime
The PCB transport (carry in) from Cnvr. Positioning 2 did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
425102 Output Cnvr. Overtime
The PCB transport (exhaust) to output machine did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
425103 Output Cnvr. Overtime
The movement to PCB receiving position did not end in prescribed time.
-----
425104 Output Cnvr. Overtime
The movement to the arrangement position did not end in prescribed time.
-----
425106 Output Cnvr. Overtime
The reversal positioning operation did not end in prescribed time.
-----
0604-003
3.3 Conveyor