1-42 AKFEMT -ID 3.3.1 1 Nozzle Stocker Section Nozzle Stocker Sliding Area Every 3 Months Cleaning and Lubrication (DAPHNE EPONEX GREASE No. 1) Required T ime: 5 minutes (1) W ipe off old grease with an oiled rag. (2) Ap…

100%1 / 235
1-41
AKFEMT-ID
PCB Detection Sensors (14 places)
Every Week Cleaning
Required Time: 2 minutes
Clean the PCB detection sensors with a
rag.
Fig. 4A32
0607-003
3.3 Inspection, Cleaning, and Lubrication Spots
1-42
AKFEMT-ID
3.3.11 Nozzle Stocker Section
Nozzle Stocker Sliding Area
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off old grease with an oiled rag.
(2) Apply new grease with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Nozzle Storage Section
Every Month Cleaning
Suck dirt and dust with a vacuum cleaner.
Fig. 4A33
0804-004
3.3 Inspection, Cleaning, and Lubrication Spots
1-43
AKFEMT-ID
3.3.12 Control Box Section
Fans (2 places)
Every 3 Months Cleaning
Required Time: 4 minutes
(1) Detach four setscrews fastening the
dust filter.
(2) Suck dirt and dust with a vacuum cleaner.
(3) Attach the dust filter and secure it with
the setscrews.
Fig. 4A34
0804-004
3.3 Inspection, Cleaning, and Lubrication Spots