cp742me_pam_operation_manual.pdf - 第17页

Fuji Software Upgrade Report (Appendix) 02022A3 17/21 htt p:/ /www.f uj i. co. jp / Copyright © 2002 Fuji Mac hine Manufacturi ng Co., Ltd. All Right s Reserved. 11. Production Program Se ttings In order to use the [PAM …

100%1 / 21
Fuji Software Upgrade Report (Appendix) 02022A3 16/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
10.Editing the Offset Tolerances
Press [Maintenance] [PAM Measure] [100%/80%] [OK] [PAM Measure] [Setting offset
tolerance] to display the following screen. The offset tolerances can be set at this screen.
Offset tolerance settings screen.
10.1Set
Press [Set] to the left of the item to be edited, and input the setting using the numerical keypad.
10.2Offset Tolerances
PAM parts which are found to be outside these tolerances when they are inspected during the
PAM placement measurement are treated as error data.
Parts which fall within the range indicated by the following function are regarded as valid.
Parts outside this range are treated as errors.
- Offset tolerance < Inspection result < + Offset tolerance
Fuji Software Upgrade Report (Appendix) 02022A3 17/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
11.Production Program Settings
In order to use the [PAM Equip] and [PAM Measure] commands, the nozzle name (GNANAM) used
in the production program must be set at the part data special nozzle name (PENNZN). By making
this setting, the parts are only placed using the specified nozzle.
“UNIT”,”NOZZLE”
"BLOCK","CP732+"
"GNANN","GNANAM"
1,"R08-007"
2,"R08-010"
3,
"R08-013"
"R08-013" "R08-013"
"R08-013" ç
çç
ç
This nozzle must be set in part data.
4,"R16-018"
5,"R16-025"
6,"R08-004"
"UNIT","PARTS"
Omitted
"ELEMENT","VISION-"
"PTPVICVT",10
"PENVILIT",0
"PTPVILCA",0
"PTPVILB",0
"AUTOHEIGHTCHK",1
"PARTHEIGHTTOL",0
"PTPVIPL",0
"ELEMENT","ENVDT"
"LEVEL1","CP732ENVDT-"
"PENNMI",1.3
"PENNMA",1.3
"PENNZN",
"R08-013"
"R08-013" "R08-013"
"R08-013" ç
çç
ç
For PAM placement and measurement.
"PENBLM",9
Omitted
Fuji Software Upgrade Report (Appendix) 02022A3 18/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
12.Saved Files
The files are saved when the [File Save] command is selected at the PAM measurement commands
screen. The files have the following format.
PAMNEW_512_CP7.PGO [100%]
Panel SeqNo Mode X Y Q (1/1000mm,1/1000degree)
P1 N 1 F -113 -396
P1 N 2 F -65 -324
P1 N 3 D 162 -63 148
P1 N 4 D 143 86 408
P1 N 5 D 138 13 285
P1 N 6 D 175 -26 486
P1 N 7 D 156 -10 372
P1 N 8 D 157 -62 545
P1 N 9 D 198 -34 -57
P1 N 10 D 67 -14 -357
P1 N 11 D 104 -52 444
P1 N 12 D 190 -34 19
P1 N 13 D 221 46 361
P1 N 14 D 129 -16 -41
P1 N 15 D 131 -17 191
P1 N 16 D 90 -24 53
P1 N 17 D 145 -7 450
P1 N 18 D 153 -69 390
P1 N 19 D 152 -25 -3
P1 N 20 D 130 69 769
P1 N 21 D 156 27 295
P1 N 22 D 206 -22 228
P1 N 23 D 177 1 768
P1 N 24 D 156 -50 525
P1 N 25 D 192 -10 -133
X USL Y USL (1/1000mm)
100 100
X LSL Y LSL (1/1000mm)
-100 -100
All data. X(1/1000mm) Y(1/1000mm) Ang(1/1000deg)
X Y Ang
4 -5 187
3sigmaX 3sigmaY 3sigmaAng
333 330 918
6sigmaX 6sigmaY 6sigmaAng
666 660 1836
dXmax dYmax dAng max
231 206 1164