cp742me_pam_operation_manual.pdf - 第7页

Fuji Software Upgrade Report (Appendix) 02022A3 7/21 htt p:/ /www.f uj i. co. jp / Copyright © 2002 Fuji Mac hine Manufacturi ng Co., Ltd. All Right s Reserved. 4. Measuring th e PA M Placement Press [Maintenanc e] - [PA…

100%1 / 21
Fuji Software Upgrade Report (Appendix) 02022A3 6/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
3.5.2 Carrying Out PAM With the Cam Speed at 100% and Updating the
Machine Data
1. From the main screen, press [Maintenance] - [PAM Measure], and then set the
cam speed to 80%.
2. Select [PAM Equip] and START to carry out the placement of the PAM parts.
3. Press [PAM Measure] and START to carry out measurement of the placement
accuracy.
4. Press [Renewal] to update the machine data.
Note: Make sure that the program selected is suitable for production at a cam speed of
100%.
3.5.3 Calibration Data Batch Conversion
Calibration data is batch-converted, including that for non-measured nozzles, when
using [Calib. Data Batch Conv.] command. Calibration data for measured nozzles,
however, is used for those of non-measured nozzles.
[Main] [Maintenance] [PAM Measure] [Cam Speed Selection Dialog]
[100%]/[80%] [OK] [PAM Measure] [Renewal] [Update Proper Data]
Screen [Calib. Data Batch Conv.]
Fuji Software Upgrade Report (Appendix) 02022A3 7/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
4. Measuring the PAM Placement
Press [Maintenance] - [PAM Measure] - [PAM Measure] - [100%/80%] - [OK] - [PAM Measure] to
display the following screen and enable the START button. Press START to begin the
measurement. The vision monitor displays during the measurement.
PAM placement measurement screen.
4.1 Move Mode
Measurement can be carried out in Continue or Step mode.
4.2 Result
The deviation results for the measurement of PAM part placement are given for each
sequence as 3
σ, 6σ, Max., Min., Cp and Cpk.
4.3 Indicate Distribution
The distribution diagrams of the measurement results display.
4.4 File Save
The results are saved as a file.
The results files are saved at “¥Fuji¥User¥Data” in order with the names “Pam001.Dat” to
“Pam005.Dat”. The format of the files is described later in this document.
Fuji Software Upgrade Report (Appendix) 02022A3 8/21
http://www.fuji.co.jp/
Copyright © 2002 Fuji Machine Manufacturing Co., Ltd. All Rights Reserved.
4.5 Renewal
The results are used to update the machine data placement offset items.
4.6 Editing Offset Tolerances
The offset tolerances can be edited.