Installation and User manual Sleeve cleaning station 10/2007 Edition 17 2 Inst allation and User Manual Sleeve Cleaning S t ation 2.1 Product description The proper preven tive maintenance of slee ves ensures the smooth …

100%1 / 30
Installations- und Betriebsanleitung Pinolenreinigungsstation
Ausgabe 10/2007
16
1
1
Installation and User manual Sleeve cleaning station
10/2007 Edition
17
2 Installation and User Manual
Sleeve Cleaning Station
2.1 Product description
The proper preventive maintenance of sleeves ensures the smooth operation of SIPLACE place-
ment equipment with respect to pick up reliability and component placement. 2
Up to now airborne dirt and dust which have accumulated over time within the sleeve are cleaned
manually with various drill bits. However, this manual cleaning procedure consumes a significant
amount of the maintenance staff’s time. 2
The SIPLACE Sleeve Cleaning Station is designed to perform the cleaning procedure in a most
systematic, easy and efficient way: 2
– simple operation, no special knowledge necessary
– reduced time of sleeve cleaning
– uniformed quality of cleaning.
2.2 Scope of delivery
2.3 Necessary tools
Set of Allan wrenches 2
1
Main Unit
1
Two pins AC input power cord (1 metre)
1
User manual (Item no.: 00194653-xx)
Installation and User manual Sleeve cleaning station
10/2007 Edition
18
2.4 Safety instructions
This User Manual contains notes that must be observed to guarantee your personal safety and to
avoid damage to equipment. 2
2.4.1 Qualified personnel
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and preventive maintenance of automatic placement systems and add-on devices and
are suitably qualified, e.g.
– have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
– have been trained or instructed in the upkeep and use of appropriate safety equipment in ac-
cordance with normal safety standards.
– have received first aid training.
2.4.2 Use as prescribed
The product must only be used for its intended purposes as described in the catalogs and techni-
cal descriptions, namely the placement of SMD components, and only with the third-party equip-
ment and components recommended or permitted by SIPLACE. Use for a different or extended
purpose is not prescribed.
If the product is not used as prescribed, SIPLACE accepts no liability for any damage that may
occur and does not guarantee that the components will work properly and without problems.
Use as prescribed also includes compliance with all the instructions in the user manual.
For the product to operate correctly and reliably, it must have been transported, stored, erected
and assembled correctly and must be operated and maintained with care.
2.4.3 Failure to use as prescribed
Failure to use the product as prescribed can result in both danger to life and limb and material
damage. For this reason any use that is not prescribed is not allowed. If the product is not used
as prescribed, SIPLACE accepts no liability for any damage that may occur and does not guaran-
tee that the components will work properly and without problems.
Failure to use the placement machine as prescribed includes, for example
– the operation of the station without safety cover or with safety cover without function.
– the cleaning of sleeves with ddifferent length of shafts.