Installation and User manual Sleeve cleaning station 10/2007 Edition 23 2.8 Inst allation : Connect the power cable to the connector at the back of the unit and to the power outlet (see photo below). : Connect the air ho…

Installation and User manual Sleeve cleaning station
10/2007 Edition
22
2
2
2
1 Power connector
2 Air hose
3 Air regulator
4 Nozzle jet
5 Safety switch for upper cover
a
s
d
f
g

Installation and User manual Sleeve cleaning station
10/2007 Edition
23
2.8 Installation
: Connect the power cable to the connector at the back of the unit and to the power outlet (see
photo below).
: Connect the air hose to the entrance of regulator and to the air supply (see photo below).
: Check the air regulator an adjust it to 5 bar (0.5 Mpa).
: Ensure a clean and dry supply of compressed air, use filter if necessary!
2
2
2
Power cable
Air hose
Power connector
Air regulator

Installation and User manual Sleeve cleaning station
10/2007 Edition
24
2.9 Operation
Step 1 Load 2
: Turn off power button.
: Open the upper cover.
2
There are sleeves with different lengths of ditches for the longitudinal vacuum hole, see step 2.2
2
: Select sleeves with long and short ditch.
: Place sleeves in the sleeve set plate.
: Make sure that the sleeves sit properly by rotating the sleeve gently.
: Close the upper cover after set sleeves.
: Turn on power button.
Wait until power lamp turns on.
2
Step 2 Select mode 2
There are sleeves with different lengths of ditches(4 mm) for the longitudinal vacuum hole. 2
2
2
Do not mix both types in one cleaning process.
There are different strokes for both types, the wrong stroke might damage the sleeve. 2
2
: Push Mode Selector button.
Indication light (Amber) is ON for “short stroke”,
Indication light is OFF for “long stroke”.
2
Step 3 Start / Stop 2
: Push Start button (green).
The cleaning process will start automatically.
The equipment stops automatically (15 cycles, about 3 minutes). with a buzzer signal.
The operator will be notified through buzzer signal and lashing of the stop button (red indica-
tor).
: If you want to stop the cleaning process manually, push the STOP button (red).
Sleeves until 02/1997 26,5 mm
current series 30,5 mm